20 Most Recent Paragon 4001-00 24-hr Timer Control 120v Ac Cd101 Questions & Answers


Try Googling (paragon)(EC 74/120D)(manual) without parens.

Paragon 4001-00... | Answered on May 12, 2017


Replace trippers
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

Or replace timer with Intematic 120 volt SPST T101 timer or T171 timer with skip-a-day
http://waterheatertimer.org/Buy-T100-series-timers.html

Gene

Water Heater Timers Save Money

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

Paragon 4001-00... | Answered on Mar 28, 2015


Humming from the timer is not normal. If the timer is still keeping the time accurately it should not be a problem. If the time is innacurate the motor may be failing. Unfortunely this timer is out of production and a replacement motor may be hard to get.

M3017-00 is the motor rated for 120VAC service or M3191-71 is the motor rated for 208/277VAC service.

You can try one of the following to source this motor if you need it.

Grainger 800-323-0620 http://www.grainger.com
Graybar 800-472-9227 http://www.graybar.com
Johnstone (5032563663 http://www.johnstonesupply.com
Munroe Electric 800-777-0172
Atlanta Supply 800-972-5391 http://www.atlantasupply.com
WestsideWholesale 18779397979 http://www.westsidewholesale.com

Paragon 4001-00... | Answered on Jan 15, 2015


heres a list of places that you can get them Grainger 800-323-0620 http://www.grainger.com
Graybar 800-472-9227 http://www.graybar.com
Johnstone (503) 256-3663 http://www.johnstonesupply.com
Munroe Electric 800-777-0172
Atlanta Supply 800-972-5391 http://www.atlantasupply.com
Westside Wholesale 1-877-939-7979 http://www.westsidewholesale.com

Paragon 4001-00... | Answered on Jan 15, 2015


Does the manual override lever move back and forth as trippers pass? If NO, then trippers are bad
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000
http://www.amazon.com/dp/B00441YVCO/?tag=waterheaterti-20

120 Volt timer.
When timer is ON, test across terminals 2 and 3 for 120 Volt
If 2 and 3 show 120 volt, then timer is delivering power on schedule. Look for loose connections. Loose wire nuts.
If 2 and 3 do not show 120 Volt, then timer has failed.
Suggest buy T101 as replacement for durability and generic replacement parts.
http://waterheatertimer.org/Buy-T100-series-timers.html

Crossover wiring from Paragon 4001-00 to Intermatic T101
Paragon 1 to Intermatic 1, Paragon 2 to Intermatic 2, paragon 3 to Intermatic A


If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

Paragon 4001-00... | Answered on Nov 05, 2014


Use following troubleshoot table for paragon or intermatic box timers.
http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timer.html

Add comment and say what you discover, and for more assistance

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

Paragon 4001-00... | Answered on Apr 19, 2013


Timer not identified.
Copy following links.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#Paragon4000
http://waterheatertimer.org/pdf/How-to-operate-and-set-T104-timer.pdf

Add a comment and describe timer in detail.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

Paragon 4001-00... | Answered on Apr 12, 2013

Not finding what you are looking for?
Paragon 4001-00 24-hr Timer Control 120v Ac Cd101 Logo

85 questions posted

Ask a Question

Usually answered in minutes!

Top Paragon Hardware & Accessories Experts

Gene Haynes

Level 3 Expert

5353 Answers

Thomas F. Schneider

Level 3 Expert

2715 Answers

jdthefixer

Level 3 Expert

746 Answers

Are you a Paragon Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Paragon Hardware & Accessories

  • Paragon Hardware & Accessories

Most Popular Question

paragon 4001 00 timer timer seems

  • Hardware & Accessories
Loading...