Sharp AR-5316 Advanced Digital Imager Copier - Page 7 - Answered Questions & Fixed issues


WHEN THE SHARP AR-5316 PHOTOCOPIER IS SWITCHED ON THE ERROR CODE 4H APPEARSAND THE MACHINE CANNOT BE OPERATED. IHAVE TRIED THE SOLUTION SUGGESTED JUNE THIS YEAR BUT IT DID NOT WORK. WHAT CAN I DO TO GET THE MACHINE TO WORK? IT IS VERY URGENT.

Sharp AR-5316... | Answered on Nov 03, 2018 | 9,688 views


u2-40

Sharp AR-5316... | Answered on Jul 29, 2013 | 30 views


I need operating code AR-5316

Sharp AR-5316... | Answered on Jul 19, 2013 | 165 views


light copies replace drum kit

Sharp AR-5316... | Answered on Jul 08, 2013 | 82 views


your copier mainbord has problem!

Sharp AR-5316... | Answered on Jul 07, 2013 | 30 views


you have a wrong toner chips, replace your toner cartrages

Sharp AR-5316... | Answered on Jul 07, 2013 | 14 views


check your exposure lamp to fix this

Sharp AR-5316... | Answered on Jul 07, 2013 | 341 views


The error code H4 is a fuser error code. The cause is one of the following fuser lamp, thermal fuse or the thermistor.

Sharp AR-5316... | Answered on Jun 09, 2013 | 197 views


A H4 error code relates to the fusing unit not reaching the desired temperature within the time limit. This could be a heat lamp or thermistor failure. I recommend calling a local service engineer to take a look.

Sharp AR-5316... | Answered on May 09, 2013 | 72 views


It sound like you have a thermistor that either has a buildup on it or it is not contacting the fuser roller. I would remove the fuser, disassy and clean every component. Reinstall and usually the problems go away. Let me know if you need more assistance.

Sharp AR-5316... | Answered on Mar 12, 2013 | 198 views


Hi there,

Well F2 error codeis on a variety of Sharp copiers, the F2 error code would normally be accompanied by a sub code that indicates the fault, You may please check out the following -

  • F2 with sub code 00 - Toner Sensor problem, ID pattern reading error;
  • F2 with sub code 02 - Toner Motor problem, check toner dispenser motor;
  • F2 with sub code 31 - Image Density error, Check the light level or the drum surface reflectivity;
  • F2 with sub code 32 - Drum Mark sensor, missing/dislocated mark or sensor faulty. Sensor cannot scan mark properly;
  • F2 with sub code 33 - grid voltage wrong, either too high or too low;
  • F2 with sub code 35 - grid voltage correction will not work during simulation;
  • F2 with sub code 37 - drum mark sensor adjustment required.
You may post further comments for more help or information......

Good Luck!!

Thanks for using FixYa!!

Sharp AR-5316... | Answered on Feb 13, 2016 | 3,797 views


What is the rest of the code it must be L1-00 or sumthing

Sharp AR-5316... | Answered on Mar 07, 2013 | 16 views


what is the supply voltage in ur area is it 220v or 110v.Most european machines are 110v and this creates problem with the fusing section.H4 code is from fusing unit .U can check the machine ratings by looking at the back or side cover where they are mentioned. is it i ok then check for broken thermistor,heater

Sharp AR-5316... | Answered on Mar 05, 2013 | 153 views


There are lots of reasons for paper jam...
... Take a look where it always happen.. There might some paper stuck on its path why its always Jam.. or the sensors are blind... get a paper.. roll it and blow it on the sensors... and sometimes broken parts..

Sharp AR-5316... | Answered on Mar 04, 2013 | 60 views


Your problem in the fuser unit.Check and clean the heater lamp,thermistor or thermostat.

Sharp AR-5316... | Answered on Mar 04, 2013 | 88 views


Hello sir; F2 have a sub code, press print key to read the sub code, if the sub code is 04,then it means wrong cartridge,wrong country, you can try to reset it;
1, press "#", "interrupt", "c", "interrupt" keys.
2, enter 14 press start.
3, if it work, don't forget give me a good rating.

Sharp AR-5316... | Answered on Mar 04, 2013 | 1,144 views


replace the toner ic or toner cartridge

Sharp AR-5316... | Answered on Mar 04, 2013 | 25 views


HI! I HAVE BOUGHT THE SHARP PRINTER/COPIER/FAX/SCAN MODEL AR-M155, WHEN I INSERTED THE NEW TONNER AND MAKE THE PHOTOCOPY TESTING I GOT THE OUTPUT COPY WHICH SHOWS THE HALFED COPY IN VERTICAL ON RIGHT HAND SIDE WHEN YOU READ THAT PAPER SO WHAT COULD BE THE PROBLEM ON IT WHILE IT IS NEW MACHINE???? AM SCARED!!!. PLEASE IWOULD BE VERY HAPPY IF YOU HELP ME TO SOLVE THIS MY REQUEST PROBLEM.

THANKS,

Aggrey34

Sharp AR-5316... | Answered on Mar 04, 2013 | 460 views


clear the memory of the machine, change the destination of the toner or fixe in a new toner crum or also known as toner sensor

Sharp AR-5316... | Answered on Mar 04, 2013 | 696 views


error f2

Sharp AR-5316... | Answered on Feb 26, 2013 | 3,166 views

Not finding what you are looking for?
Sharp AR-5316 Advanced Digital Imager Copier Logo

1,371 questions posted

Ask a Question

Usually answered in minutes!

Top Sharp Office Equipment & Supplies Experts

Anthony Karuku

Level 2 Expert

268 Answers

amir hamza
amir hamza

Level 2 Expert

318 Answers

k24674

Level 3 Expert

8081 Answers

Are you a Sharp Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...