Check for ice build up sounds like an issue with your defrost cycle

Haier... | Answered on Aug 11, 2013


it can be but probaly cost more than the refrigerator.

Haier... | Answered on Jul 01, 2011


Hi,

Many times a freezer and/or refrigeratordo not work right because of a dirty condenser coil...there are also many otherthings that can go wrong. If you are hearing a clicking or buzzing then check out thelast two tips.

If your refrigerator is running but warm, then...

Check out this tip that I wrote about that... it is a great place to starttrouble shooting your unit...and something that you can do rather then callinga repair person to do a simple thing for you...

Refrigerator Condenser Coil Cleaning Refrigerator Repair

Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay
Refrigerator or Freezer not Cooling or Getting Cold

heatman101

fsjkh

Haier... | Answered on Sep 29, 2010


Hi,

As the weather is getting warmer for many people their freezer2_bing.gif and/or refrigerator do not work right because of a dirty condenser coil...

Check out this tip that I wrote about that... it is a great place to start trouble shooting your unit...and something that you can do rather then calling a repair person to do a simple thing for you...

http://www.fixya.com/support/r4024657-refrigerator_condenser_coil_cleaning


http://www.fixya.com/support/r3885294-refrigerator_troubleshooting

http://www.fixya.com/support/r4023749-refrigerator_compressor_start_capacitor

heatman101

Haier... | Answered on Jun 04, 2010


Hi,
The drain for the water to get away when defrosting is frozen shut...
Checkout this tip to help you..

Water Running in Refrigerator from Freezer2_bing.gif
http://www.fixya.com/support/r3780310-water_running_in_refrigerator_from

heatman101

Haier... | Answered on May 27, 2010


your thermal temp switch overload on the compressor may be bad. you can buy it here and they have a800 number here is the web site with phone number.
http://www.appliancepartspros.com/partsearch/modelsearch.aspx?model=492420265334

Haier... | Answered on Apr 11, 2010


dump it....please dont waste anymore time....trust me...my 21 years of doing this is tell you.

Haier... | Answered on Nov 12, 2009


Replace the gasket.

Your local appliance parts hose should have them in stock, and if not can likely order them.

This is a common problem and quite easy to fix. Most gaskets are simply pressed into a seam in the door. A few are held in place by simple metal brackets than can be removed with a screwdriver.

Haier... | Answered on Aug 24, 2009


The fan won't work when the unit is in the defrost cycle. Some won't run when the door is open. It won't run when the compressor isn't running. Test it here>http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php And yes, you can replace it.

Haier... | Answered on Jul 11, 2009


compressor not running or defrost system not working.

Haier... | Answered on Jul 05, 2009


Check the thermostat. make sure it is turned on. The thermostat can shut it off. Also check to see if you have power to that outlet you are using. If none of that is the problem you can try and bypass the thermostat with a jumper wire( If you are comfortable with do this) Be careful when doing this cause electric shock is possible. don't touch any wires directly

Haier... | Answered on Apr 24, 2009


- Loose flooring or floor not firm.
- Cabinet not level.
- Tubing in contact with cabinet, other tubing or other metal.
- Drip tray vibrating.
- Fan hitting another part or worn fan motor bearings. Unplug the unit and rotate fan manually by your finger.
- Compressor mounting grommets worn or missing; mounting hardware loose or missing.
- Free or loose parts causing or allowing noise during operation
- Check compressor it may contact with tubing or other parts.
- Check the body of your unit is not touching the wall or other object.

Haier... | Answered on Jan 12, 2008


Interesting! I'm going to assume that this is a 110V unit running on an alternate power supply rather than regular AC. First: test the circuit with at least a 100 watt light bulb for a few minutes. If that looks okay (bulb at full brightness, not flickering), let's go on. What I also don't know is what 'overloads' you're speaking about. If it is the compressor (there is a light clicking sound periodically in or near the black compressor unit), the problem could be that it is overheating because something is blocking the airflow around the coils like an ant nest or debris. You've got to go in and clean them. Unplug unit, remove the contents and glass shelves, lay the unit on its side so you can see what's what in the back. Remove anything that looks like the manufacturer didn't put it in there. Look up into the area where the tubes go into the back panel area, too. Do not clean with water! If the unit is more than 5 years old, it probably should be scrapped. Note that older units have R-12 refrigerant which should be handled only by a qualified tech or recycler.

Haier... | Answered on Nov 25, 2007


Do you have a 4" gap at sides, top and back?

when was the last time you pulled it out and vacuumed the condensor coils?

Haier... | Answered on Jul 22, 2019


In most cases hair tend to grow in a course of 4 - 6 months after hair transplant is done. In some cases it may take 6 - 12 months. There after hair growth tends to improve over time. According to the quality of the grafts implanted and perfection you may get better results in hair growth. I did my transplant from hair transplant Toronto and my hair started to grow within a span of 4 - 5 months.

Haier... | Answered on Jun 30, 2019


Hi Brett,
When the Haier refrigerator shows an error code, try this before replacing any parts or taking the refrigerator apart...
- Power the Haier refrigerator OFF for 10 minutes, then power back ON. (Unplug the refrigerator for 10 minutes) -
The error code may disappear after a reset is completed.
- If after removing power to the refrigerator in an attempt to reset, the error code comes back,the freezer fan is bad and need to be replaced.
Here is a link to Haier Parts.
Also make sure there is No Recall on your particular model or serial.
Best of luck,
JP

https://www.haierappliances.com/parts

Haier... | Answered on Jun 18, 2019


Broken compressor isolation mounts maybe.

Haier... | Answered on May 31, 2019

Not finding what you are looking for?
Haier (492420265334) Refrigerator With Ice Box Logo

Popular Tags

30 questions posted

Ask a Question

Usually answered in minutes!

Top Haier Refrigerators Experts

geob91

Level 2 Expert

128 Answers

Marvin
Marvin

Level 3 Expert

85160 Answers

Vernon Taylor

Level 3 Expert

5514 Answers

Are you a Haier Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Haier Refrigerators

  • Haier Refrigerators

Most Popular Question

mini haier 1 7 refrigerator wont

  • Refrigerators
Loading...