my dear you clean CCD camera and mirror

Kyocera FS-1118... | Answered on Mar 29, 2018


Hi

Error C6400 appears in Kyocera FS118 when Zero crossing signal problem occurs i.e when the engine PWB doesnt detect the zero crossing signal. This can occur due to --

#1 Poor contact in the connector terminals.
#2 Defective power supply PWB.
#3 Defective engine PWB.

To reset it from Mainatince mode turn the power switch off and open the front cover. Now, turn the power switch on and press the system menu/counter key to enter the maintenance mode.

1. Press the enter key. A selection item appears.
2. Select Execute using the up/down cursor keys.
3. Press the enter key. The fusing problem data is initialized. (Four service calls, namely C6000, C6020,
C6050, and C6400 are reset.)
4. After this is complete press the back key. The indication for selecting a maintenance item No. appears.

Daniel Scott

Kyocera FS-1118... | Answered on Sep 23, 2017


scanner unit dusty please clean than solve problem

Kyocera FS-1118... | Answered on Sep 10, 2016


Calling a service person might lead to correction.

Kyocera FS-1118... | Answered on Aug 27, 2016


you chek heater unit and fouse

Kyocera FS-1118... | Answered on Jul 08, 2015


This might take some doing reseting the fs 1118 but it can be done if the fuser only got hit by a powersurge or overheated due to paperjam by the fuser...

press system menu/counter
select service settings via up and down cursor keys

now while pressing start key and # key press enter

then select maintenance mode by using the up down cursor key

press enter

enter 163 and then restart the copier...

sometimes you wont even be able to get to the service mode...

open the front of the copier and then execute the steps... the front meaning the area where you the toner is located...

trying keeping it open and do the steps...

if that fails then open it take out the toner drum cartridge and then put it back in...

then do the steps...

if it still doesn't take try it a couple more times...

if it still doesn't take.. buy a new fuser...

but it should take... it just takes a little experimentation...

I’m happy to assist further over the phone at https://www.6ya.com/expert/norman_d2fa496dce30c65d

Kyocera FS-1118... | Answered on Mar 23, 2015


It means the exposure lamp is not turned on. Either a connector has come loose or the exposure lamp and/or the inverter pwb and/or the control pwb must be replaced

Kyocera FS-1118... | Answered on Jun 11, 2014


Check the toner sensor under the processing unit (PU).
Remove the PU and you will see in the front left side, inside the machine, a black sensor (a black part with cross screw on it and a spring underneath it. There is a possibility that sensor to be dirty or damaged.
An important question is... is the toner original or compatible with appropriate chip (toner id)?

Kyocera FS-1118... | Answered on Jun 03, 2014


If the code is C6400, then just follow the procedure showing in the images below.
If the code is C6000, then you have to remove the fuser unit and check the thermistor, the thermal cut out and the heater lamp. If are able to fix the problem-damage, then follow the procedure below to reset the service call.
b6abe89e-6db1-403f-b1d5-10039126b726.jpg 6bbf89df-5e1f-4ba9-830e-5fa3e278ce55.jpg

Kyocera FS-1118... | Answered on Jun 03, 2014


1-4-1 Maintenance mode
The machine is equipped with a maintenance function which can be used to maintain and service the machine.
(1) Executing a maintenance item
Select Service setting using
the up/down cursor keys.
The selected maintenance item is run.
Press the back key.
Press the enter key.
Start
End
The maintenance item is
selected.
Maintenance mode is exited.
Maintenance mode is entered.
Repeat the same
maintenance item?
Run another maintenance
item?
Turning power switch off and back on
No
No
Yes
Yes
Select Maintenance mode using
the up/down cursor keys.
Enter the maintenance item
number using the up/down keys.
While pressing the start key and the # key,
press the enter key.
Press the system menu/counter key.
Press the enter key.
* The test print mode cannot be stopped until the preset number of sheets is printed. To stop the operation, remove the
cassette to cause a paper empty state. To terminate the test print mode in the middle of operation, you must turn off the
power switch and then on again to exit the maintenanc
when in maintenance mode go to 163 to reset

Kyocera FS-1118... | Answered on May 09, 2014


Works with ERROR C6000, C6300, C6400

Switch off
Open Toner Cover
Switch on, holding "System Menu"
Go to "Secure Setting"
"Enter"
Hold "Start" "#" "Enter"
Scoll down to "Maintenance Mode"
"Enter"
Scoll down to "U163"
Scoll do "Execute"
"Enter"
Close Toner Cover
Leave run for a few seconds
Switch off
Switch on....

I’m happy to help further over the phone at https://www.6ya.com/expert/ron_9356d26241d4cbf7

Kyocera FS-1118... | Answered on May 04, 2014


replace the fuser will fix that. Or if you want to stip it down check the lamps and if their ok change the thermistor and thermostat. But your better off just replacing the whole unit

I’m happy to help further over the phone at https://www.6ya.com/expert/ron_9356d26241d4cbf7

Kyocera FS-1118... | Answered on May 04, 2014

Not finding what you are looking for?
Kyocera FS-1118 Printer Logo

59 questions posted

Ask a Question

Usually answered in minutes!

Top Kyocera Office Equipment & Supplies Experts

Marvin
Marvin

Level 3 Expert

85161 Answers

Adorjani Laszlo

Level 3 Expert

1316 Answers

gggg

Level 3 Expert

904 Answers

Are you a Kyocera Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

FS Kyocera

  • FS Kyocera

Most Popular Question

error c3200

  • Office Equipment & Supplies
Loading...