Just inboxed a master built smoker go to turn it on control panel beeping and say eaa1

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

  • Expert
  • 82 Answers

It usually means the short temperature probe in the unit is too cold or wet. Hit it with a hair dryer for a minute or two. That should solve the problem. If you live in a cold climate, this could be an ongoing, but easily addressable issue.

Posted on Jun 09, 2019

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad
  • 7 Answers

SOURCE: used the masterbuilt smoker only 5 times???

I just bought a new Masterbuilt Smoker by default two weeks ago I borrowed a friend’s to smoke about 30lb. of Salmon to then can. Ran the smoker every day for three day. ON my last batch the heating element would not work. Talk about Frustrated! The Smoker was only 2 yrs. old.

Knowing I borrowed I felt I had to replace. So online to Cabelas and I ordered my buddy a new smoker and had it shipped. I then found this website... GOT TO LOVE the internet. I saw many other people had the same problem. Found an Answer...

The Problem was one of the connector to the heating element was poor quality and if you don't clean your smoker on a regular basis. The heat and moister caused the small copper connector to corrode and the wire to come loose. I took a wood chisel and cut off all the rivets on the back. I was then able to pull the back off with no damage and access the small box in the lower back. I found the connector. Went to the hardware store and bought a replacement for .75 cents. A pair of wire crimpers and the problem was fixed. I also bought ½ inch Sheet metal screws to secure the back it was good as new. So I returned the smoker to my buddy and kept the new one. When it arrived I saw Masterbuilt has since fixed the problem and provided an access panel to the element and connectors.

Mike in Alaska

PSU313@yahoo.com

Posted on Jul 03, 2010

  • 1 Answer

SOURCE: masterbuilt electric smoker is brandnew

Had the exact same problems. I took off the electronic control unit and made sure the probe was still connected (unplugged and checked the pins for damage). After reassembling the unit everything worked fine. My guess is that the probe was not properly connected, therefore it was showing 32 deg all the time. Once it was properly connected, the actual temperature showed on the display. Hope that helps.

Posted on Mar 26, 2011

heatman101
  • 43501 Answers

SOURCE: I have an electric master

Hi,
Everything you want to know is right here...

http://dadgumthatsgood.com/blog

heatman101

Posted on May 18, 2011

app_3rp36331
  • 1 Answer

SOURCE: I need to replace the fire rack and bowl for my

I bought a replacement charcoal bowl for a charbroil h20 smoker for $12 on their website. It fits the same but lacks the air holes (I made my own). For the rack, I got some wire cutters and cut my own out of an old steel refrigerator rack. It works.

Posted on Sep 11, 2012

  • 304 Answers

SOURCE: Master Built Smoker will not over 200 degrees

Hello!

Here you can find manuals for Master Bilt electric grills.
Hope it will help. Seems that there is a problem is with the heating element.
http://manualsbrain.com/en/brands/master-bilt/electric-grills

Posted on May 30, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

We bought a new masterbuilt electric smoker. When we power it on, we get the message EAA1 and it shuts off.


Take off the electronic control unit and make sure the probe is still connected (unplugged and check the pins for damage). After reassembling the unit everything should work fine. My guess is that the probe is not properly connected, Once it was properly connected, the actual temperature showed on the display. Hope that helps.

Dec 23, 2017 | Masterbuilt Grilling

1 Answer

My master built electric smoker is not holding the 200 degree heat?


How cold outside was it and was there wind? Even though they are insulated smokers you still have to help block the wind. And was your damper open? Keep it cracked open, if it's open all the way your losing all the heat and the element has to keep running to reach temp. Otherwise inside you should had a round metal fuse n next to that should be a rod sticking out from the back wall that is your temp control sensor it might have junk on it giving false reading, just wipe off with damp cloth. Hope this helps

Nov 16, 2016 | Grilling

1 Answer

Why am I getting an EAA1 error after 5 minutes of first use?


READ FIRST!
Before trying any of the lengthy suggestions regarding repairs on Masterbuilt electric smokers, consider this. It APPEARS (based on testing, not reverse engineering) that Masterbuilt designed the controller on my unit (140S) to error out below a certain minimum temperature. If you are like me and have your smoker outside (as you should), but in sub freezing temperatures, you too may get this error. Just shoot the short temperature probe (on the back wall of the cabinet) with a hair dryer for a minute or two. Then plug back in for no error (assuming you do not have an actual wiring or probe failure). Just make sure to immediately start it heating before it drops too low again...

If this was by design, shame on Masterbuilt! If this was by error, shame on their engineers! If this behaviour is due to an intermittent problem with my unit, shame on me for not fully testing all possibilities once I found an easy fix...

Jun 23, 2014 | Masterbuilt 20070411 30" Electric Smoker...

1 Answer

I got it for christmas and it has quit twice. "We are so tired of expecting to smoke meat for friends and family and having to end up putting it in the oven. The first time was the heating element....


Ideas?/ Yeah, it's apiece of junk! Electrical problems plaque the Master Built Electric Smokers. If it's not the heating element failing, it's the control panel failing. That's why it only has a 90 day warranty from the time of purchase.

As to what to do is concerned, replacing the control panel should solve the problem. Here is a link to the part and you can purchase it online.

http://www.appliancefactoryparts.com/search/partinfo.php?partsID=491507&modelsID=135884&typeName=gas%20grill

Hope this helped you and thanks for choosing FixYa.

Sep 09, 2011 | Masterbuilt 20070106 Electric Smoker

1 Answer

Masterbuilt electric smoker is brandnew plugged it in runs for about 5 minutes then flashes EAA1 and showing the temp is 32??


Had the exact same problems. I took off the electronic control unit and made sure the probe was still connected (unplugged and checked the pins for damage). After reassembling the unit everything worked fine. My guess is that the probe was not properly connected, therefore it was showing 32 deg all the time. Once it was properly connected, the actual temperature showed on the display. Hope that helps.

Feb 25, 2011 | Masterbuilt 20070106 Electric Smoker

1 Answer

I am getting a EEAF fault code and the smoker will not heat. What is wrong?


To RESET control panel:
If control panel shows an error message, turn electric smoker off, unplug unit from outlet, wait
ten seconds, plug unit back into outlet, then turn electric smoker on. This will reset control panel.

ASSEMBLY, CARE & USE MANUAL
WARNING & SAFETY INFORMATION
MODELS 20070106, 20070206


If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

Nov 25, 2010 | Masterbuilt 20070106 Electric Smoker

1 Answer

The F7 code appears with a beeping noise. How do I turn off the beep for good.... selecting clear/off only works for a few seconds


Hi,

Well, F7 error code occures due to
A = Function pad button stuck or 
B = Bad clock Unstick button or
Replace Electronic Range Control (ERC)

Replace the ERC there are ten screws 3 on each side and 4 on the control leave the hex screws alone all you need is a phillip screwdriver.
REMEMBER TO SHUT OFF THE POWER FIRST lift and fold out the control panel remove the ribbon cable and remove the four screws that hold the control board . replace control panel in reverse order.

Thanks

May 27, 2009 | GE Built-In 24" Double Electric Wall Oven

4 Answers

Kenmore electric built-in oven control panel beeping


We had the same problem. F7 error code and beeping. We turned off at the breaker- left it off for hours turned it back on and still f7 and beeping. We call repairman to come out and he removed the cover on control panel (3 screws on bottom of controll panel and it pops off). He unplugged the ribbon keypad connection - Cleaned the ends with a pencil eraser and said it is fixed and we would not have a problem.

Well, that was a fast way to spend 60 bucks but it has been a week and the oven has been great. No more beeps or error codes. SAVE YOUR MONEY DO IT YOURSELF!

Oct 08, 2007 | Ovens

Not finding what you are looking for?
Grilling Logo

Related Topics:

37 people viewed this question

Ask a Question

Usually answered in minutes!

Top Grilling Experts

Paul Carew

Level 3 Expert

3424 Answers

Marvin
Marvin

Level 3 Expert

85111 Answers

Tom Chichester

Level 3 Expert

52795 Answers

Are you a Grilling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...