I have Vissani model HVDR430SE fridge. It runs all the time. It keeps cool not cold. I assume this to be the thermostat. Where can I get a schematic and thremostat?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • Refrigerators Master
  • 52,834 Answers

Vissani would be a possible source for both.

Posted on Jun 16, 2019

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad
  • 1 Answer

SOURCE: Refrigerator warm, freezer too cold

I had this same problem. You need to totally empty the fridge and freezer and allow it to defrost for 24 hours. Then put it back on and it will work. This happens if someone leaves the freezer door open and then it gets closed. The defrosted water freezes in the pipes and doesn't allow the cold air to move up into the fridge so the freezer gets even colder. This has happened to me twice!

Posted on Aug 16, 2008

huuum
  • 750 Answers

SOURCE: Candy CPCA250 GB Freezer feezing but fridge not cold

Hello jonnyclewlow
Welcome,


You said, you recently had a problem with my Candy fridge freezer (it defrosted overnight and wasnt cooling at all) and a repair shop diagnosed a thermostat problem. I have replaced the thermostat, Now the freezer freezes without any problems but the fridge does not go cold at all.
Also the compressor is running constantly

This is my first thought

Fresh Food temperature is
too warm. Freezer
temperature is satisfactory.

1. Fresh Food control is set too
warm.
2. Set fresh food control to a colder setting. Allow 24
hours for temperature to stabilize.

3.Then see if you do not have your freezer articles packed full up to the top, or covering the cold air vents usually found in the rear of the freezer compartment.

The fridge and the freezer share the cold air so the air must not be restricted from travel form the freezer to the fridge and back!
This would also cause the compressor to run none stop trying to cool the fridge!
So check your air vents in the freezer.
I'll bet you did not know they were there !
Most of us never notice!
Hope this works for you.
Please let me know that one of these solutions worked for you!
or if you have any questions.
Thank You, huuum
Please remember to leave a rating!

Posted on Oct 14, 2008

SOURCE: I have a zanussu fridge

Re. Zanussi ZK87/46EFS Fridge Freezer

The same symptom occurred in our fridge freezer. The fridge compartment warmed up whilst the freezer compartment continued to keep temperature.

The cause of our problem was diagnosed as a frozen sensor that controls a flap, that controls the flow of cold air from the freezer compartment up into the fridge compartment. We were advised to power off the fridge freezer (removing all food and trays from the freezer unit first), and to leave it to defrost for 24hrs. We needed to place a few towels on the floor of the freezer compartment to soak up the melt water. After 24hrs we followed the power up instructions in the manual (versions are available online if you have lost yours). Within a few minutes it was obvious that the fridge compartment was being cooled – Problem solved :)

Posted on Nov 01, 2008

joecoolvette
  • 5660 Answers

SOURCE: Frigidaire model ftr18b freezer works, fridge is only cool

Info relating specifically to the Frigidaire FRT18B5ABB:

1.Refrigerator unplugged remove the bottom back panel. (Access cover with label. The rectangular shaped panel on the back, at the bottom) Place the screws in a container.
Also remove the Kickplate Grille in the front, and the defrost pan.

2.Use the wand tip on your vacuum cleaner, and vacuum this area out. Pay special attention to the condenser coils, and the fan. Use care as you don't want to bend the fan blades. After you have vacuumed up as much as possible, see if your vacuum has where you can attach the hose to blow air through it. An air compressor, hose, and air nozzle would be REAL handy right now! Blow the condenser coils, and all areas clean of any gunk. (Hair, spider webs, etc.) If this is not feasible for you, you'll need some sort of long, thin, dust 'bunny', and have to dislodge this 'gunk' physically. Then vacuum.

3.BE SURE to replace the bottom back panel, (Access Cover)! It is a VERY necessary item! If your fridge doesn't have one at present, make a temporary one of cardboard, and tape it on. This access cover is needed.

If your refrigerator side is only cool, and your freezer is cold, you may have a problem with the Cold Control, (Temperature Control), or the Defrost Timer. (Timer-Defrost)
http://disruptit.com/manualgateway.cfm?pdfwanting=34242&username=anon&AV=123345&I=99.169.118.45

Posted on Jul 05, 2009

  • 19 Answers

SOURCE: Freezer is cold but not keeping icecream frozen.

If, the fresh food section is 34- 38 degrees, then the freezer should be cold enough to keep ice cream solid. All of the cooling capability comes from the freezer section. I, personally, would not waste time or money on a ten year old box. Ten years ago it cost $1000, so, the outlay is $100 per year. Dump the old refrigerator and get a new one.

Posted on Aug 27, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Does outside unit run when thermostat calls for auxiliary heat ?


do not think so . that unit is usually for cooling .

Apr 03, 2018 | Heating & Cooling

1 Answer

I purchased a vissani 90 can cooler and it clicks on and off when plugged in. It doesn't get cold


Vissani - Diagnosis Refrigeration - Dispense Forum ' Discuss Keg ...

www.micromatic.com/.../6480-vissani-diagnosis-refrigeration
Oct 25, 2009 - The back plate doesn't even get cool let alone cold. ..... Since I have kegerator parts from the Vissani I am just looking for the best frig to convert.

Refrigerator Troubleshooting & Repairs ' HomeTips


Jan 23, 2016 | Refrigerators

1 Answer

Should the fan operate all the time in my refrigerator


Most of the time it runs only when the compressor is running. In other words compressor and fans will run together when the fridge thermostat ask for cold and stops together when thermostat is satisfied. In newer fridges some time inside fan (evaporator fan) might PERIODICALLY run without compressor to circulate little cool air to fridge compartment from freezer compartment.

Sep 30, 2014 | Whirlpool Refrigerators

1 Answer

My fridge is not cold


Check the thermostat is giving power to the compressor and the condenser is clear and clean. Check all fans are working, and the evaporator (inside) isn't frozen solid. Assuming all this is ok, and the fridge components are working but it is still not cooling, it has lost it's gas charge. Time for a new one!

May 17, 2012 | Refrigerators

1 Answer

Beko CDA751FW/1 mostly on all the time - fridge 4 degC, freezer -30degC


there is no thermostat in cda751fw/1. apparently the pcb controls fridge temperature. which pcb, the main one or the one behind the temp dial I dont know which.

Apr 11, 2012 | Refrigerators

1 Answer

We have a Kenmore Elite Freezer Model #253.29082994. We had the freezer plugged in and it was working fine. We unplugged it and moved it and now when we plug it in it won't start. Is there some kind of...


You refrigerator was made by Frigidaire Adaptive Defrost Controls Frigidaire Refrigerator Trouble Shooting and Diagnosing
On the initial plugin, or when power is restored to the fridge after a power outage:
If terminating thermostat is open, the fridge enters a compressor (cooling) cycle.
If the terminating thermostat is closed, the first defrost cycle occurs 1 hour
after initial plug-in.
Maximum defrost cycle time is 24 minutes.
Minimum time between defrost cycles is 6 hours. (compressor runtime)
Maximum normal clock time between defrost cycles is 12 hours.
Maximum time between defrost cycles (in "vacation" mode) is 72 hours.
Vacation mode is not entered unless the door has not been opened in at least 24 hours.
Note that the ADC will only enter the defrost mode if the terminating thermostat is closed. If the terminating thermostat is open when defrost is initiated, the ADC board will wait for six minutes and then return to the cooling mode.
ASSUMING that the fridge has been on and running,
and the terminating thermostat is closed,
defrost is initiated by pressing the door (light) switch
at least five times within six seconds.
The defrost heater should start heating up within 8 seconds.
If the above procedure caused the heater to heat up, the ADC board is probably bad; replace it.
If the defrost heater does not heat up, test the defrost heater, terminating thermostat and cold control for continuity as follows:
Unplug the fridge from the wall. Unplug the ADC board from its connector.
Test the connector for continuity between the following leads:
Defrost Heater = DEF TERM (blue) to DEF OUT (brown).
Terminating Thermostat = DEF TERM (blue) to NEUTRAL (lt blue).
Cold Control = COLD CONTROL (orange) to L1 (black).
Replace the defective component.

dvfxnxxsllnll3xsyszyldhiovfnqznnvujbtluyw2q4uxl2ntjkcdj6njhpmxnefkntwws4bi9kdg83ay5nd0jdsnhpljetrth0supsduvxugpczlkyaszhzu1onu9xwdfjv0xta0jidtfiwg%3d%3d

Apr 26, 2011 | Kenmore Freezers

1 Answer

Frigadare freezer gets very cold, lower refrigerator gets no cold at all


This is because your refrigerator is not cooling, your thermostat does not detect the proper cooling and does not cycle off compressor - your compressor is running continually - since your refrigerator's cooling rlies on your freezer. We can rule out fan problems as your evap fan in the freezer is working - If your refrigerator is barely keeping cool but not enough you probably have a gasket leak - if it not cool at all you likely have a damper problem - the damper is a flap that gets opened / closed as needed - yours is probably stuck - when you get it serviced they will need to check damper & control boards. I assume also you have checked to see if there is any vent obstruction in your fridge.

Sep 05, 2009 | Electrolux Refrigerators

1 Answer

Freezer is cold but not keeping icecream frozen.


If, the fresh food section is 34- 38 degrees, then the freezer should be cold enough to keep ice cream solid. All of the cooling capability comes from the freezer section. I, personally, would not waste time or money on a ten year old box. Ten years ago it cost $1000, so, the outlay is $100 per year. Dump the old refrigerator and get a new one.

Aug 27, 2009 | Refrigerators

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

58 people viewed this question

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

Marvin
Marvin

Level 3 Expert

85111 Answers

Brad Brown

Level 3 Expert

18067 Answers

Gil Shultz

Level 3 Expert

3388 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...