Question about Honda Electrical Supplies

1 Answer

MY BLACKMAX 7000/8750 RUNS GOOD BUT THERE IS NO ELECTRICITY GENERATING, HOW DO I FIX THIS?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Master:

    An expert who has achieved Level 3.

  • Master
  • 255 Answers

Most of the time it is either the Capacitor or AVR that has blown (depending on what is fitted on your generator.). Check out our videos on how to test them.
We hold a full range of Generator AVRs and Capacitors. https://www.generatorguru.com

We have a whole Help Center and Engineers dedicated to helping people fix their Portable Generators. In addition to this we have a "Parts Search Service" if the part is not listed on our site. Check us out on our site. https://www.generatorguru.com/
Parts Spares for Generators and Small Engine Machinery

MY BLACKMAX 7000/8750 RUNS GOOD BUT THERE IS NO EL - image-2fwsrbehqcya13uxwt41l5dc-5-0_4.jpg

Posted on Aug 19, 2019

Ad

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad
  • 35 Answers

SOURCE: my g5501r stopped generating,engine runs

There is at least one and possible two fuses and one most likely has failed. You need to remove the blow fuse and replace it. Mine were the size of two D sized batteries put together. I have a generak 10k and I experience same problem. I purchased two new fuses and all is well.

Posted on Aug 25, 2011

  • 3289 Answers

SOURCE: The motor is running but it is not generating electricity.

Here's a link to your manual:
http://www.managemylife.com/mmh/lis_pdf/OWNM/L1001172.pdf

No power is a result of a break in the output circuit of the generator. The most likely places for this to happen are at connection points and moving parts designed to open and close manually and automatically. These include terminal screws and push on type connectors, switches and circuit breakers.

Before beginning, you should follow the troubleshooting chart for "..No AC Output" on Page 21 of the manual.

Since there is a great deal of vibration on the entire unit, it is not unlikely to have open connections where there shouldn't be. A careful disassembly of the control box with the unit off and disconnected from the electrical panel should allow you to poke around without fear of shock or burns. It would be a good idea to take a picture or two of the connections when you open the box - before disconnecting anything. otherwise, be sure to label wires and terminals for anything you take apart.

Look for evidence of arcing or sparking. This is usually a blackened area near a terminal or wire. Clean the contact area and determine where the connection point is supposed to be and complete the circuit as per the schematic. Check for loose wires "floating" in air (aka not connected to anything). Reconnected as shown by the schematic. Next, apply pressure to all terminals and connectors to find any that are loose. Resecure any found. pay attention to those on DP1, DP2 and the 240 volt 30 amp outlet.

Using the schematic on Page 22, check the 25 Amp circuit breaker identified as CB1 by removing wires 11A and 44A from this circuit breaker's terminals. Use a multimeter set on Ohms (or resistance), set and zero to the lowest range, and test from the terminal with the #11 wire on it to the terminal that had 11A on it. With the circuit breaker ON, it should read less than a couple of Ohms. This is a closed circuit indication. Repeat tests with terminals 44 and 44A. If you lack a meter, you should be able to use a continuity light (this will cause a light to illuminate when there is a good battery in it and there is a connection or path between the probes of the light). The meter resistance should indicate an infinite amount of resistance when the circuit breaker is turned off (as the light should go off when the circuit breaker is turned off, too). This is the open circuit indication. If the meter never indicates a closed circuit with the breaker ON, the breaker should be replaced. If it works as expected, reconnect the 11A & 44A wires to their original terminals.

Continue to test each CB2 and CB3 the same way. Remove wire 11B from the terminal of the circuit breaker and test from wire 11A to the circuit breaker terminal that 11B was connected to. With the breaker ON, it should show as closed circuit. When off it should show open circuit. If not, replace the circuit breaker. Reconnect 11B to the circuit breaker terminal. Lastly, move to CB3 and Remove wire 44B from the terminal of the circuit breaker and test from wire 44A to the circuit breaker terminal that 44B was connected to. With the breaker ON, it should show as closed circuit. When off it should show open circuit. If not, replace the circuit breaker. Reconnect 44B to the circuit breaker terminal.

The rest of the check out requires that the generator is running and voltage measurements be taken. As little as 50 volts can kill under the right conditions, so extreme caution must be exercised. If you have never worked on these systems before or are
not completely comfortable working with voltages levels this great, you should stop at this point. Otherwise, check for the presence of 240 volts on CB1 terminal 11 & 44. If not present, there is a problem with the voltage regulator or generator windings themselves. Repairing or replacing these parts may not be worth doing depending on age of the generator, etc.

I hope this helps & good luck!

Posted on Jan 11, 2012

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I am not getting any speed and power from my Nissan caravan non turbo zd30 diesel engine and it is just smoking when I press the gas


generator set will occasionally encounter generator failure in the process of use thatCummins generator setis not generating electricity. What is the cause of it? And what to do about it? In fact, there are a lot of reasons that Cummins generator set is not generating electricity. The following is compiled by Jiangsu Starlight Electricity Equipment Co.,Ltd to summarize the main reasons for generator not to generate electricity and the treatment methods.

Sep 01, 2018 | Nissan Cars & Trucks

1 Answer

I have a pacific 7500 generator that stopped gerating electricity. Motor starts and runs great but no volts coming out


Generating section is no good. Check to see if there is an open circuit breaker in system.

Jan 01, 2016 | Electrical Supplies

1 Answer

Microwave runs but doe not heat


follow this test and fix it. God bless you
  1. Check the power diode This electronic component is responsible for transmitting current in one direction. If the diode becomes defective it will cause your microwave to not heat. Test the diode and replace it if necessary.
  2. High voltage capacitor Responsible for storing electricity, this part is a key component in any microwave. Remove, discharge, and test the capacitor to determine if it requires replacement.
  3. Damaged magnetron Responsible for generating waves and producing heat. When your microwave is no longer heating properly, replacement will be required.
  4. Thermal Cutoffs Examine the thermal cutoffs on both the magnetron and the oven itself. Take off one of the leads and using a volt-ohm meter on RX1, check the terminals. If you get a result other than zero, replace the thermal cutoffs.

Nov 26, 2013 | GE JVM1190 Microwave Oven

1 Answer

It runs but won't heat, what do I do?


please follow this test and fix it. God bless you
  1. Check the power diode This electronic component is responsible for transmitting current in one direction. If the diode becomes defective it will cause your microwave to not heat. Test the diode and replace it if necessary.
  2. High voltage capacitor Responsible for storing electricity, this part is a key component in any microwave. Remove, discharge, and test the capacitor to determine if it requires replacement.
  3. Damaged magnetron Responsible for generating waves and producing heat. When your microwave is no longer heating properly, replacement will be required.
  4. Thermal Cutoffs Examine the thermal cutoffs on both the magnetron and the oven itself. Take off one of the leads and using a volt-ohm meter on RX1, check the terminals. If you get a result other than zero, replace the thermal cutoffs.

Nov 22, 2013 | Hamilton Beach Microwave Ovens

1 Answer

My g5501r stopped generating,engine runs fine,everything on but no electricity


There is at least one and possible two fuses and one most likely has failed. You need to remove the blow fuse and replace it. Mine were the size of two D sized batteries put together. I have a generak 10k and I experience same problem. I purchased two new fuses and all is well.

Aug 25, 2011 | Makita 2,800 Watt 6 Hp Portable Power...

1 Answer

Honda ems 4000 generator starts and runs great, but no power


At the controller, you need to see if it is actually sending electricity out of the Generator/Alternator, have a look where the leads from the power making unit mates, (Think of it as a motor in reverse) onto the board. There should be an AC Voltage there, then, work back, or out from there, trace the Voltage until it stops, thats the problem... Check the Breaker isn't tripped or faulty too.

Mar 22, 2010 | Electrical Supplies

2 Answers

My Kohler Confidant IV generator starts and runs great for about 30 seconds and then dies,, starts right back up and does same thing, what is up with that


Kohler generators feed the generated voltage back into the control circuit board to tell it to keep the fuel pump (electric) runing and the ignition on. IF there is no voltage generated (bad brushes or?) then the symptom you describe will occur. The motor runs fine, but it isn't generating electricity.
Jim Russell

Mar 30, 2009 | Electrical Supplies

2 Answers

My powermate pm0647000 stopped generating electricity.


Flash it !
Start your generator, plug a single speed drill into the recepticle, while the generator is running make sure the drill is in the forward posistion then turn the drill chuck couterclockwise with your hand untill your generator power's up.
This simple fix " excites " the stator.
Good luck !

Sep 29, 2008 | Coleman Powermate Premium Plus 6250W...

1 Answer

Generator will not generate electricity.


I assume it is a hand start genset. The most common problem if it has been sat for a while is rust on the ignition timing flywheel. If you take the pullcord housing off (recoil) then you will see a big flywheel with what can only be described as a big forked prong with a couple of wires on it. This flywheel should be stainless steel and rusts when sat around for a while without use. Its job is to complete the circuit to the spark plug every time the flywheel passes the forked prong at a given spot on the flywheel, the faster the wheel turns the faster the spark hence the engine runs quicker. Clean the rust off with a releasing agent (wd 40) hey presto!!!!!!!!!!!

Sep 17, 2008 | McCulloch 13HP 338 Cc Portable Generator #...

Not finding what you are looking for?
Electrical Supplies Logo

Related Topics:

55 people viewed this question

Ask a Question

Usually answered in minutes!

Top Honda Electrical Supplies Experts

John Trevino

Level 3 Expert

1407 Answers

Norman Al-Anbar

Level 3 Expert

630 Answers

Sheldon Dedek

Level 3 Expert

909 Answers

Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others