That sounds like a white balance issue to me. Do you use manual white balance setting or auto white balance?

Konica Minolta... | Answered 8 hours ago


black developing motor error

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

Konica Minolta... | Answered on Sep 06, 2019


The problem is in weakened solenoid's (SD2) spring (10). That solenoid located under metal cover (13) on left side of 1690MF (if look at front of them). Required solenoid has red wires. Remove metal cover with 3 screw, unscrew solenoid and just slightly stretch spring (10). That is all.
schema-wwprwdeuw1z0sk0bwersu1g4-1-0.jpg

Konica Minolta... | Answered on Sep 05, 2019


There is another cover at the down right side of machine.Below the side door.Open it and then close it.Then bring out the tray and close it.Machine will start working.if not then tell me...

Konica Minolta... | Answered on Sep 04, 2019


What are you trying to reset?

Konica Minolta... | Answered on Sep 02, 2019


You try cleaning and/or replacing the color registration assy?..
check the HV (high voltage board)..HV1 and HV2..

Konica Minolta... | Answered on Sep 01, 2019


To print the transmission report:

1. Press the [Fax/Scan] key to display the Fax mode screen.
2. Touch [FAX Menu].
3. Touch [TX Report] on the Set 1 tab.

4. Select how to output the report, and then touch [Enter].
– Default: The transmission report is printed according to the previously specified method.
– ON: The transmission report is printed with each transmission.
– If TX Fails: The transmission report is printed only if the fax could not be sent.
– OFF: The transmission report is not printed, regardless of the transmission result.

Konica Minolta... | Answered on Aug 26, 2019


take each of the image units out not toner image units. Then shake each unit along its axis to spread the developer in side each one along the whole image unit. then reinstall. next pull out the transfer belt and reinstall properly. if this does not work you might have and burned out main motor or worse the control board that controls it is bad.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

Konica Minolta... | Answered on Aug 20, 2019


Push down Stop buttom and switch on.

Konica Minolta... | Answered on Aug 19, 2019


The amount of toner in the developer is too high.

service mode.
adjust
tcr
+10

Konica Minolta... | Answered on Aug 19, 2019


1.The terminal for the first transfer pressure/release sensor is not connected properly.
Reconnect the terminal.
2.Failed PS15 (p/n 08AA 8551 2).
Test photosensor, PS15, in the I/O State Confirmation Mode, 48-0HIGH = home position or LOW = Other than home position by activating M19 (p/n 08AA
8003 0) transfer pressure/release motor, 48-0, 48-1, 48-2, or 48-3. Replace thephotosensor or motor as needed.
3. Possiblefailed Transfer/Pressure Release motor (M19).
Check the operation of the motor(p/n 08AA 8003 0) in the I/O State confirmation mode for proper operation with code 48-0; this should rotate the motor
constantly. Replace motorif needed.
Also check for possibleopen ICP fuses, ICP3 (5V DC)and ICP4 (24V DC) on the AC drive board (p/n A03U H520 01). Replace the drive board as necessary.
SPECIAL NOTE : Solution contribution by KMBT (Japan) and Freddie Burnham, Production Print/SSD

Konica Minolta... | Answered on Aug 19, 2019


C0200 - Cyan PC Drum Charge Corona Malfunction. Did you mess with this imaging unit? You won't be able to reset if the malfunction is still present.
---------------------------------------------------------------
Konica Minolta Error Codes & Solutions - http://www.kmcodes.com
Drum, Transfer Belt and Fusing Unit Firmware Reset - http://www.bizhubreset.com
Drum and Toner Chip Reset - http://www.chipreset.eu
Transfer Belt and Fusing Unit Reset Kit - http://www.resetkit.eu

Konica Minolta... | Answered on Aug 17, 2019


Thread 2704

Abnormality in the black charging unit.
Possible causes:
Black charging unit
HV Unit
Print Control Board

Best guess is that you have a faulty charge unit. Try swapping the units around with another colour and see if the fault code shifts.

Konica Minolta... | Answered on Aug 16, 2019


Abnormality in the black charging unit.
Possible causes:
Black charging unit
HV Unit
Print Control Board

My best guess is that you have a faulty charge unit. Try swapping the units around with another colour and see if the fault code shifts.

Konica Minolta... | Answered on Aug 16, 2019


this is a waste toner box error the waste toner box could be defective or the full sensor is defective i would start with replacing the waste toner box and clean the sensors on the door with some canned air the waste box and the sensors are located inside the lower front door the instructions on how to remove the waste box are on a label on the inside of the door

Konica Minolta... | Answered on Aug 15, 2019

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Konica Minolta Experts

Adorjani Laszlo

Level 3 Expert

1316 Answers

Ekse

Level 3 Expert

13434 Answers

Marvin
Marvin

Level 3 Expert

85161 Answers

Are you a Konica Minolta Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...