20 Most Recent Black & Decker Steam Xpress AS250 Iron with Auto Shut-off Questions & Answers


Hi.
As a suggestion, I would put some white vinegar 1 part to 5 parts water through the iron to clean away the mineral deposits. Let it soak cold for an hour or so. If it has just stopped steaming action  from the steamer button, heat the iron up and put plenty of action through the button also. It will have mineral deposits there also. As for any instructions on service, there will be none in print. I suggest running around the edges of the plastic cover parts with a guitar pic(if you have one) or something of a flexible springy nature. The clips at the edges can generally be released in the manner. Good luck
regards robotek

Black & Decker... | Answered on May 28, 2017


Hi,
The cord is broken...

Here is a tip that will help you to troubleshoot your iron and figure out what is wrong with it.

Electric Iron not Heating Up or not Working Right
http://www.fixya.com/support/r5300202-electric_iron_not_heating_up_or_not

heatman101

Black & Decker... | Answered on Apr 25, 2015


TOO HOT will make one stick

Black & Decker... | Answered on Mar 30, 2015


Just open your flat iron and locate the face plate contactor that has a soot burn causing the filament not to heat,use a sand paper to clean the contact from soot burnt,this the common problem of a flat iron...


Hope this may help;

Regards,
VOTIT

DON'T FORGET TO RATE;

Black & Decker... | Answered on Oct 05, 2013


Sorry to say !! The only solution is to replace the iron water and power don't mix !!!! Safty First

Black & Decker... | Answered on Oct 10, 2011


Bring the iron to a Hardware store, ask for a set of tools right for the type of screws (maybe Torx, Security Torx, tri-wing, bristol and others).

Once you can open the iron and access to the cord you may change the power cord. it is easy.

Power goes on & off because the power cord is broken. This failure is very common on irons.

Good luck

Black & Decker... | Answered on Apr 20, 2011


You need to check the following for circuit contintinuity:-
The plug and wall socket
The leads, both the live and the neutral
The temperature selector (Thermostat)
The thermal fuses
The element

To do this testing you will have to strip the iron and get to the wire ends, the thermal fuses and the element terminals. (My guess is that it is the thermal fuses. They are little metal tubes wires attached and are usually insulated in white fibre glass tubing and attached to the element plate).

Black & Decker... | Answered on Feb 25, 2011

Not finding what you are looking for?
Black & Decker Steam Xpress AS250 Iron with Auto Shut-off Logo

Popular Tags

70 questions posted

Ask a Question

Usually answered in minutes!

Top Black & Decker Irons Experts

Colin Stickland
Colin Stickland

Level 3 Expert

22485 Answers

Brad Brown

Level 3 Expert

18121 Answers

John Egan
John Egan

Level 2 Expert

85 Answers

Are you a Black & Decker Iron Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Black & Decker Irons

  • Black & Decker Irons

Most Popular Question

iron just stopped heating

  • Irons
Loading...