I have a Windsor Sensor s12 and power shuts off after 5 min. of vacuuming. I'm wondering if it's overheating of if there is some other sensor that causes it to shut off.

After we let it cool off for a few minutes it will start again but only run for a few seconds.

Posted by on

Ad

4 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Windsor Master
  • 1,604 Answers

Your Sensor most likely has an internal heat sensor that is shutting off the motor. Some vacuums install an external heat sensor with a reset button that you must push to re-start the vacuum. If your model does not have an external reset button it is most likely a sensor inside the motor. If it is defective the motor must be replaced to solve the problem. But first make sure the overheating is not being caused by a blockage somewhere or the bag is too full. Air must pass completely through a vacuum starting at the floor where it picks up the dirt through all the canisters, filters, bags, etc. and then is exhausted from the vacuum. Any restrictions or blockage can cause the motor to over heat.
That Vac Guy

Posted on Oct 19, 2013

Ad
  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    New Friend:

    An expert that has 1 follower.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 110 Answers

The Sensors are great machines as are the Versamatics. I've found that if the Sensor is shutting off then cleaning or replacing the "hygiene filter", the tall filter inside the bag compartment, normally fixes the problem, letting the motor "breathe" easier. The bag full and clog sensors wear out over time. I own two and those lights are constantly on.

Posted on Dec 01, 2015

Ad
  • Level 1:

    An expert who has achieved level 1.

    New Friend:

    An expert that has 1 follower.

  • Contributor
  • 1 Answer

I have a question for you... my sensor s12 - the motor cuts in and out as the machine is moved from verticle to horizontal positions as well in the vertical position when pushed as far forward as possible.

I have changed the cord/handle no effect.
changed filters/bag no effect

pinched or broken wire?

Posted on Feb 10, 2015

  • Level 1:

    An expert who has achieved level 1.

    New Friend:

    An expert that has 1 follower.

  • Contributor
  • 1 Answer

Hi Chris! question, we have couple of windsor S12 vacuum, but most of them as a same issue with Bad full and Clog light on, even we change new bag and clean all the host, but sill that red light come on and after sometime, vacuum itself shuts down automatically. any troubleshooting for this case. we cleaned the brush, filter, change new bag and clear all the host, but still same issue with red light on. need help badly.
thanks

Posted on Jan 19, 2015

3 Suggested Answers

6ya6ya

6ya staff

  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Anonymous

  • 6 Answers

SOURCE: No Power to Windsor Sensor XP12

The Windsor Sensor vacs all have a removable handle.

The handle is inserted into a "socket" which has contacts to complete the electrical circuit.

The handle is held in place by a gray plastic lever.

If the lever is not pressed down completely, the handle is able to slide within the socket during regular use.

If the handle slides out far enough, the electrical connection within will be disconnected and the vac will have no power.

Simply lift the lever, pull up to remove the handle, and re-insert the handle fully, then press down firmly on the lever to lock the handle securely in place.

This is the first step to solve your problem and hopefully this is all that need to be done.

If this does not work, please repost here and I will help you all I can.

Note: I am a big fan of the Windsor Sensor vacs and find them to be easy to work on and a great vac all around!

Posted on Feb 25, 2010

VacuumRepair

Chris Jones

  • 438 Answers

SOURCE: how do you change the belt on a winsor sensor s12?

Step 1. Remove the vacuum bag housing so that you are only working with the power nozzle or the bottom portion of your Sebo, this will make it much easier to work with. Turn the vacuum upside down, and remove only the 5 screws that I have circled in red:


9b05567.jpg

Step 2. After removing the screws on the bottom of the vacuum cleaner, separate the top housing from the lower agitator housing, sometimes it may take putting a flat head screw driver in between the white and grey colored housing and prying them apart.

Step 3. You now have full access to the belts on your machine. It's most likely the belt that wraps around the brush gear rather then the belt that's attached to the motor that's gone bad. I have never replaced the motor belt in 8 years of servicing Windsor vacuums.

If you have any further questions on how to replace the belt, please feel free to reply to this repair by leaving your question in the comment section, I'm always more then happy to answer any question you may have.

Thanks again,

Chris Jones
goVacuum.com

Posted on Apr 27, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Bikegit


Replace the switch! It shut down when battery get depleted. and then when you start it again the cycle is shorter because the batery regenerate but not as previous cycle.

Jul 16, 2014 | Karcher WV50 Window Vacuum

1 Answer

The unit won't run, shows overheating flashing light, we let kit cool, start again and it runs for only a few seconds until it quits again.


possible your motor stock up try to check capacitor or the bearing apply lubricants or replace bearing if needed

Feb 19, 2011 | Hoover Platinum Collection Upright Vacuum

1 Answer

BB1100BdD stops after a few minutes operation. After an hr or so will run again for a few minutes


The motor is overheating and control features cause it to shut off to prevent burning it out. First check the bag. If it is full, remove and replace with a new one. A full bag can cause the motor to work harder, and thereby overheat. Next check the filters. A dusty filter will keep air from cooling the motor and again cause overheating. The HEPA filter needs to be checked also. Most filters can be dusted off. Some can be washed, air-dried, and replaced.Others will need to be removed and replaced. Your owner's manual should tell you how to clean filters. I hope this helps. If it solves your problem, please let Fixya know and post a rating for my solution.

Nov 19, 2010 | Oreck BB1100DB / BB1100DC Housekeeper...

2 Answers

Stop working. brush was cloged. It there a reset button?


i had a similar thing happen and just got off the phone with dyson. there is a resettable switch on the handle. they told me to start the vacuum in the upright position, put it in the non upright position, then push and hold in the beater bar switch which is located next to the on/off button for 10 seconds and the beater bar should start to function once again

Jul 15, 2010 | Dyson DC07 Animal Bagless Upright Cyclonic...

1 Answer

It runs for a couple of minutes shuts off then restarts 30 seconds later runs a couple of minutes and does this over and over


Most vacuum motors are protected from overheating by a thermal switch that resets after cooling down. Check for blockage in the hose,
power head or a full bag that would block cooling air from cooling the motor.

Tom

Oct 22, 2009 | Tristar Vacuums

1 Answer

Stops after a few minutes


Its overheating, so the TOC (thermal overload cutout device) is cutting the power to the motor to protect it.
Thats why it works when it has cooled down.
Check for blockages and make sure the filters are clean, if it still happens take to an approved engineer to check the TOC

Sep 20, 2009 | Hoover U6630-900 WindTunnel Bagless...

1 Answer

Keeps stopping.


your battery isn't holding a charge ,buy a new battery

Mar 25, 2009 | iRobot Roomba Discovery SE Bagless Robotic...

1 Answer

Dyson Quits


cut out switch on the motor needs replacing this overheats and cuts of the motor when the motor cools down it will start again you have to keep both filters and cyclone clean and free of dust or after replacement the same will happen again

Sep 04, 2008 | Dyson DC07 Bagless Upright Cyclonic Vacuum

1 Answer

Dyson


the automatic cut out switch on the motor needs replacing when the motor gets hot this switch comes in and stops the motor from overheating when the motor cools down the cleaner will work again and cut out again when the motor gets hot if it is not replaced it will eventually burn the motor out after the switch has been replaced both the filter and cyclone need to be cleaned on a regular basis or the same will happen again

Sep 04, 2008 | Dyson DC07 Bagless Upright Cyclonic Vacuum

Not finding what you are looking for?
Windsor SR12 Sensor Bagged Upright Vacuum Logo

4,603 people viewed this question

Ask a Question

Usually answered in minutes!

Top Windsor Vacuums Experts

Mike

Level 3 Expert

4363 Answers

Strech
Strech

Level 3 Expert

1562 Answers

Raymond Richards
Raymond Richards

Level 3 Expert

407 Answers

Are you a Windsor Vacuum Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...