Question about Ariston Technologies Washing Machines

1 Answer

F08 Ariston Washer/Dryer Stops Suddenly

Hello, I have a Ariston AMD 149 (DE) Washer/Dryer. I searched for everything reagarding the error F08. I searched for an repair manual (without success). I disassemble the top cover and the back cover. I took a meter and meassured the ohms of the heater above for the dryer an the heater for the washer 31 Ohms. I changed the PCB and the pressure switch, with an identical machine (in our family we got the same two). So the solutions described for this error are:So far I did this: Wash Heater Relay Stuck (signalled in presence of empty) or pressure switch stuck on Full (simultaneously empty and full),Check the efficiency of J3 connector contact on the card, Check pressure switch status checking J3 wiring connector pins 2 and 4 ohm continuity (it must only be present with tub empty) and pins 2 and 3 ohm continuity (it must only be present with water in the drum) and pins 2 and 1 ohm continuity (it must only be present with water in the tub above normal level, at least halfway up door glass), Check wiring J3/pressure switch,Check connection of heating element J3 connector pins 5 and 6, Replace pressure switch,Replace Card ... nothing helped. Strange thing is: - normal washing program stops after the main washing program. washing powder is used. no water in the drumm and the machine stops with error F08. The motor of the Pump is working the whole time (there is maybe 0,3 liter in it if I open the lid of the pump at the bottom), the motor of the dryer fan is working the whole time. After a few minutes the Pump stops, after 2 minute the fan, than the machine just displays F08. The fabric softener is not released at this time. This happens after the washing an heating cycle.. When the error occurs it flashes in the display. a few seconds the motor of the fan on the top is still working (just the fan) then everything stops. If I choose another programm like only rinsing and tumbling it works as an part-programm. Also an stand alone drying programm is working.I already changed the board but the same problem. Yesterday I check all the wiring from the PCB to the pressure Switch. I checked the pressure switch itself, checked all the functions with a meter everything works. The small hose is not damaged. Now I saw the the fabric softener was released one time. The bottom heater is working fine. Yesterday I tried a programm with drying at the end. It shows F08 the drying cycle was not initiated. The cloth inside seems like washed and moist not wet. So it seems like the whole normal washing cycle could have been properly done. But I can not explain myself what F08 could be. If it is not the PCB (Board), The wiring, the pressure switch, the heater, what could it be. Could it be the NTC or something else? Also I have read about the filter. So I opened the bottom lid. As far as I could reach with my finger there was nothing in the way. Is there a pump filter place somewhere else? could this really a pump filter problem? Again I would like to describe what happens when the error F08 starts flashing. Someone any ideas?

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    New Friend:

    An expert that has 1 follower.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 4 Answers

Please zynga poker

Posted on Feb 23, 2014

Ad

3 Suggested Answers

6ya6ya

6ya staff

  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Anonymous

  • 209 Answers

SOURCE: hotpoint wd62 washer dryier (aquarius 1200)

i am a retired engineer of 20 years, and its about a year since i worked on combination washer/dryers but if the heater elements fine and power comes from timer there must be cut out somewhere around where it should warm up, look all round the machine one may be hidden or hard to spot there maybe about 3 one of them one of them could be a trigger device (you can press a button to reset it) that style is a very small cube about the size of a sugar lump with2 spades on it, others look like a small flat oval or round shape the size of a five pence piece with 2 spade wires on them, remove the plug from wall and remove these spades and check the contacts for continuity, you need not remove from machine to do so, no circuit + no heat, replacement item not expensive, thats where to start based on the information given, check the sensors you mention again, it sounds like your so close, good luck and work safe

Posted on Sep 09, 2007

beltronic205

Gerry Harvey

  • 1481 Answers

SOURCE: Hotpoint Aquarius cycle not finishing with f02 error

Dont think its pressure switch.if sticks one way machine overfills the other brings on heater with empty drum..Could be fauly rinse solonoid valve...Check with multimeter coil should read around3k ohms..good luck

Posted on Sep 29, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Washer stops working and displays F6


hotpoint?

"EVO1 Washing Machines and Washer Dryers" open="0" style="2"]
  • F01 - Short circuit motor triac*
  • F02 - Motor jammed tacho detached*
  • F03 - Wash thermistor open/short circuit*
  • F04 - Pressure switch jammed on empty*
  • F05 - Pressure switch jammed on full*
  • F06 - Program selector error*
  • F07 - Heater relay stuck*
  • F08 - Heater relay cannot be activated*
  • F09 - Incompatible eeprom*
  • F10 - Pressure switch not sensing correctly*
  • F11 - Pump cannot be activated*
  • F12 - Communication error*
  • F13 - Dryer fan or dryer thermistor faulty*
  • F14 - Dryer element faulty*
  • F15 - Dryer element relay faulty*
  • H20 - Not fillings. Check tap, hose and inlet valves
  • LOCKED - Check interlock*

Aug 24, 2015 | Washing Machines

1 Answer

What does f8 Mean?


F08: Resistance Missing or Pressure Switch stuck on Full Found

  • Overhaul CN1
  • Overhaul Resistance Connection
  • Overhaul Pressure Switch Connection
  • Replace Resistance
  • Replace Pressure Switch
  • Replace Card

Dado

Jan 11, 2015 | Ariston Technologies AWD120 13 lb. Washer...

2 Answers

What is F08 error means in Ariston washing Machine


You did not specify model!

F08 - Heater relay cannot be activated
  • Check wiring
  • Check pressure switch and connections
  • Tap relays as they can jam on new boards
  • Check electronic control PCB
  • Check heating element

Dado

Jun 21, 2014 | Ariston Technologies Washing Machines

1 Answer

Avtxf 149 f-08


F08 - Heater relay cannot be activated

  • Check wiring
  • Check pressure switch and connections
  • Tap relays as they can jam on new boards
  • Check electronic control PCB
  • Check heating element

Dado

Jun 21, 2014 | Ariston Technologies Washing Machines

2 Answers

F08 Ariston Washer/Dryer Stops after Wash Cycle


I can tell you about a Company which supplies the Public and Appliance repairmen. That Company is Servall. It may be hyphenated, like Serv-All or similar. They may have Manuals. They know what they sell and may be able to tell you what they sell a lot of.

Another place is often on the Radio, "The Appliance Doctor" which may be on the Web too. I want to say the Founder is Bill Gagnon; I think his son may be doing it now. They may have an E-mail.

You are lucky to have a second unit to get test parts from. Probably good idea is to put your Control head into the second machine and see if it malfunctions in the test unit. Then you would know if it is the Control head or something still in your "Box".

If I read this problem correctly, that the Fabric softener is not being released, then maybe the solenoid that releases the softener is bad and responsible for the error.

Feb 20, 2014 | Ariston Technologies AWD 129 NA Washer/...

1 Answer

Stops near end of cycle and on/off light and drying high heat light flash


error code f08-htr relay stuck-ckeck htr not open citcuit-connections on board are clean especialy botton connecters-if still throws error then req new board

Nov 12, 2009 | Hotpoint Ariston Aquarius WD420 Front Load...

1 Answer

Hotpoint Aquarius cycle not finishing with f02 error


Dont think its pressure switch.if sticks one way machine overfills the other brings on heater with empty drum..Could be fauly rinse solonoid valve...Check with multimeter coil should read around3k ohms..good luck

Sep 29, 2009 | Hotpoint Ariston Aquarius WD420 Front Load...

Not finding what you are looking for?
Washing Machines Logo

Related Topics:

449 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ariston Technologies Washing Machines Experts

Gerry Harvey
Gerry Harvey

Level 3 Expert

1481 Answers

Marvin
Marvin

Level 3 Expert

85222 Answers

Harjeet Singh

Level 2 Expert

109 Answers

Are you an Ariston Technologies Washing Machine Expert? Answer questions, earn points and help others