Question about Danby Refrigerators

Open Question

Danby fridge D9504W freezer is working fridge won't get cold?

Posted by Anonymous on

Ad

6 Suggested Answers

6ya6ya

6ya staff

  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

douglas smith

  • 1462 Answers

SOURCE: fridge not working

almost certainly a compressor fault. not worth repair

Posted on Sep 02, 2008

Ad

Anonymous

  • 1 Answer

SOURCE: freezer working but fridge is not getting cold

Its a kenmore side by side 59652673200

Posted on Oct 15, 2008

Tyler T

  • 35 Answers

SOURCE: Fridge won't get cold

Check to make sure that the fan in the freezer is running whenever the compressor turns on to cool the unit down. If the fan's not going, warmer moist air from the fridge will make the air duct frost up. The fan needs to be running to blow the cold air into the fridge section.

Posted on Apr 28, 2009

woodchuck789

Charles T Nevin

  • 4070 Answers

SOURCE: the fridge is cold but the freezer won't freeze

The grill being the condenser coil- The sealed system is low on freon or the compressor isn't working correctly.

Posted on Jul 01, 2009

localwonder

Michael Masters

  • 6784 Answers

SOURCE: Freezer works fridge not cooling on a Danby Designer fridge

HI, you will need to inspect the compressor to make sure it is cycling in intervals. if the compressor is not cycling, this will confirm compressor failure. The evaporator fan blows cold air into the freezer and from there it vents into the refrigerator. Occasionally the vents between the freezer and refrigerator can become clogged with ice, food or other debris. In most refrigerators the cold control for the refrigerator opens and closes these vents. That mechanism may become inoperative resulting in the vents becoming stuck open or closed.

Inspect the vents to determine what is preventing the free flow of air. An overcrowded refrigerator or freezer may be the cause. In other cases the vents may need to be cleaned or ice melted away. To remove a build up of ice, use a hair dryer set to "low". Using a higher setting may damage the freezer. CAUTION: Do not let melting ice drip onto the hair dryer. In some models, the vent is located under the temperature control console. The housing either snaps into place or is held in place with screws. Remove the screws, or gently depress the retaining clips with a small screwdriver. Allow the housing to hang by its wiring. A freezer vent control may also have to be removed to access the vent. In some freezer-on-top models, it may be necessary to remove the floor of the freezer to inspect for obstructions.

The condenser coils dissipate heat. If dust and debris accumulate around the coils, your refrigerator may not be able to cool properly, it may run continuously or it may stop completely as a result of an overheated compressor. You should clean rear-mounted coils once a year. Unplug the refrigerator before cleaning. Refrigerators are heavy, never tip one forward or backward. Never attempt to move a refrigerator without an assistant. Vacuum or brush the coils. If coils have a filmy build-up, use warm soapy water to clean them. Take care not to spill or drip water onto the components of the refrigerator.You should clean floor level coils at least twice a year. Unplug the refrigerator before cleaning. Vacuum or brush the coils. Remove the grill from the front of the refrigerator and use a vacuum with a wand attachment to remove any dust and debris. The grill should snap off and on. Pull firmly toward you and possibly upward to remove the grill. If it does not come off with a modest effort, check for screws or retaining clips that may hold it in place.

Another inspection point will be the door seals. This is a easy way for the cold air to escape from your unit as well. thsi will cause the temperature to rise. The seal should make smooth continuous contact with the refrigerator case. When the seal does not seal completely, warm air enters the appliance. This results in more frequently compressor operation and possibly the inability of the appliance to maintain proper temperature. To test the seal, use the dollar bill test. Place a a dollar bill or a piece of paper between the seal and the refrigerator and close the door. Now pull the paper out. You should feel tension as you pull. Retest along the entire door seal. Replace the seal if the test was unsuccessful.

Next will be the door switch. The interior light in most refrigerators, and the fan in some, is controlled by a door switch. When the door is closed, the switch is depressed and the interior light goes off and the fan resumes normal operation. If the door is misaligned or the switch malfunctions, the refrigerator may become warm as a result of the non-operation of the evaporator fan and the heat generated by the interior light. Test the switch for continuity using a multimeter. Set the multimeter to the ohms setting X1. Place a probe on each terminal. The multimeter should change from a reading of infinity to zero when the probes touch the terminals. With the probes still touching the terminals depress the switch, the reading should change back to infinity. If it does not pass both of these tests, the switch should be replaced.

Be sure to confirm evaporator fan function as well. if the fan is defective, it will prevent proper cooling as well.

This will conclude the most common issue with a under preforming unit. I would advise to check all the above and, if the unit continues to not cool after all the above adjustments are made, i will recommend replacing the cold control device and thermostat.

Posted on Jul 30, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

My danby refrigerator model # DFF092C1BSLDB stopped cooling, the freezer is still working fine. This is brand new


Cold freezer air is not properly being diverted to refrigerator section. Check out damper and controls for same.

Sep 02, 2017 | Danby Refrigerators

1 Answer

My refrigerator is warm but the light inside turns on and i have it set to cold, it just stopped working today


Have you unplugged the fridge sir? checked for any electrical disconnections? dust clogging your tubules in the back? Enough space between the wall and fridge in the back? sometimes these will do it. Your fridge needs air to oxygenate the tubules so that it does not overheat and not work.

Jan 07, 2014 | Danby DFF282WDB 10.0 cu. ft. Freestanding...

1 Answer

Freezer working, fridge not


Hi,

Check out these tips...they can help you figure out what is going wrong withyour refrigerator and why it is not cooling

Refrigeratornot Cooling or Fridge not Cooling

How to Defrost Refrigerator DefrostTimer Problem

WaterRunning in refrigerator from Freezer

Refrigeratoror Freezer not Cooling or Getting Cold
heatman101

Jul 06, 2011 | Danby Refrigerators

1 Answer

Bottom freezer left open overnight. Freezer does not work anymore. Top fridge does not getting cold as it should be.


Your fridge gets it's cold air from the freezer. If the freezer is not working then the fridge won't get cold.

May 26, 2011 | Refrigerators

1 Answer

Freezer is fine, but fridge is not very cold. Is there an easy solution.


Hi,

Check out these tips...they can help you figure out what is going wrong with your refrigerator and why it is not cooling

Refrigerator not Cooling or Fridge not Cooling

How to Defrost Refrigerator Defrost Timer Problem

Water Running in refrigerator from Freezer


Refrigerator or Freezer not Cooling or Getting Cold

heatman101

Nov 16, 2010 | Danby DFF1144BLS

1 Answer

I was chiping ice from my danby fridge freezer section, and chipped a notch out if the freexer, and now its leaking something that smeels bad, and the fridge now does not get cold and the freezer doesnt...


guess who is going to buy a new unit....NEVER USE ANY HARD/SHARP OBJECT TO AID A QUICK DEFROST.use only car deicer,then wash out with clorine bleach then dry thoroughly.
the cost of repair/recharge/callout, is going to be nearly the cost of new.

Aug 25, 2010 | Danby DCR412SS Stainless Steel Compact...

1 Answer

Freezer freezes, fridge not cold, smells very exhaust like


Hi,

Check out these tips...they can help you figure out what is going wrong with your refrigerator and why it is not cooling

Refrigerator not Cooling or Fridge not Cooling

How to Defrost Refrigerator Defrost Timer Problem

Water Running in refrigerator from Freezer


Refrigerator or Freezer not Cooling or Getting Cold


heatman101

Jul 20, 2010 | Danby (DAR604BLS) Refrigerator

1 Answer

Fridge/Freezer cools intermittently


It could be the thermostat. When you catch it in a cycle where it's warming up, gently tap the dial with the handle of a screw driver. If it starts chances are it's bad. If you know electricty you can jump the two terminals on the thermostat to do this test.

Aug 25, 2009 | Danby 3.6 cu. ft. / 102 liter Chest...

1 Answer

Fridge not working


almost certainly a compressor fault. not worth repair

Sep 02, 2008 | Danby Designer DAR1102W Refrigerator

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

169 people viewed this question

Ask a Question

Usually answered in minutes!

Top Danby Refrigerators Experts

William Miller
William Miller

Level 3 Expert

9179 Answers

Cindy Wells

Level 3 Expert

6048 Answers

Marvin
Marvin

Level 3 Expert

85216 Answers

Are you a Danby Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides