Question about Maytag Refrigerators

2 Answers

I have a Maytag model # MFI2568AES. I changed the main control board but am unable to change the code to the one printed on the inside of the fridge. I've tried several times but it continues to beep

Model #MFI2568AEs

Posted by on

Ad

2 Answers

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Habit-Forming:

    Visited the website for 3 consecutive days.

    New Friend:

    An expert that has 1 follower.

  • Expert
  • 53 Answers

We've found that certain codes are unique to certain control board. Only certain codes will program with certain board part numbers. If the code will not program, the control board and code might not be compatible. The wrong control board may have been purchased. (some of these newer boards dont actually replace the older boards they claim to) I recommend replacing the control board in your refrigerator with the exact control board part number printed on your board.

We have no longer available control boards for this model in our inventory for sale, and we rebuild them. All control boards we sell and repair are fully tested for 100% functionality & come with a two year warranty.
Reach out to us for more information.
512-355-1108
fixyourboard.com

Posted on Aug 07, 2019

Ad

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Master:

    An expert who has achieved Level 3.

  • Master
  • 530 Answers

You should have got a new code for the NEW board. it is a microprocessor. like a password.

Posted on Oct 29, 2014

Ad

6 Suggested Answers

6ya6ya

6ya staff

  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Anonymous

  • 1 Answer

SOURCE: Maytag MFI2568AES Stainless Steel Bottom Freezer

Dear jorge, I had the same problem when my refrigerator was broken. You need to re-program the control panel as follows: 1. First you need the Program Code for your fridge. It is on the plate on the inside of your fridge, on the same plate that has your Model # and Serial # on it. 2. Programming is done with the refrigerator doors open. 3. Press and hold the Door Alarm keypad on the control panel. 4. Then press and hold the Freezer Temperature Down keypad. 5. Then release the Door Alarm keypad and wait 3 seconds. 6. The control pad will then display PE to indicate it's in programming mode. 7. Entry is confirmed by pressing the Freezer Temperature down keypad once more. 8. The control panel will display the current program code. It should be the same one that I asked you to find in Step 1. 9. If the program code is the correct one, exit the programming mode by closing the refrigerator doors. 10. If the program code is not the correct one for your refrigerator, press the Refrigerator Temperature Up or Down to change the value with each keypress. 11. The decimal point indicates the selected digit. Press the Freezer Temperature Up or Down to select the next digit. 12. Once the desired program code is displayed, press and hold the Freezer Temperature down keypad until the program code begins flashing, indicating that it's been saved. 13. Again, when you're done, exiting the program mode is done by closing the refrigerator doors. Hope this helps alot of people out there. I'm not sure what the problem is at Maytag, but they're extremely slow in getting parts shipped for their units. The local Maytag repair people have indicated to me that they are seeing an overwhelming number of Maytag refrigerators needing repairs that are around the one year age range. They say the quality of the new units is terrible.

Posted on Jul 08, 2007

Anonymous

  • 116 Answers

SOURCE: new just need manual

Try the following link:

http://shared.whirlpoolcorp.com/product_literature/search_results.jsp?searchTerm=mfi2568&siteCd=MT_EN_US


Posted on Jul 28, 2008

Anonymous

  • 2 Answers

SOURCE: programming code not working

Go to this web page to find the text answer below: http://www.fixya.com/support/t233614-reprogram_hv_board

HERE TIS RIGHT OFF THE INSTRUCTION SHEET.  THE TECH JUST LEFT. POWER UP REF. PROGRAM CODE IS LOCATED ON SERIAL PLATE ON THIS UNIT AFTER THE WORD CODE.-1. PRESS & HOLD THE DOOR ALARM KEYPAD.-2. PRESS & HOLD FREEZER TEMP DOWN KEYPAD.-3. RELEASE DOOR ALARM KEYPAD AND WAIT 3 :WILL DISPLAY PE TO INDICATE PROGRAMMING MODE-5. ENTRY IS CONFIRMED BY PRESSING TEMP DOWN - KEYPAD ONCE MORE.-CONTROL WILL DISPLAY CURRENT PROGRAM CODE. THIS VALUE SHOULD BE VALIDATED THE THE PROGRAM CODE PRINTED ON UNIT SERIAL PLATE.-NOTE: IF PROGRAM CODE IS CORRECT, THE PROGRAMMING MODE IS EXITED BY CLOSING THE FRIG DOOR.-7.PRESS REFRIG TEMP UP KEYPAD + OR REFRIG DOWN KEYPAD -TO CHANGE THE DIGIT VALUE WITH EACH KEY PRESS.-8.THE DECIMAL POINT INDICATES THE SELECTED DIGIT. PRESS THE FREEZER TEMP UP KEYPAD + TO SELECT NEXT DIGIT.-9.ONCE DEIRED PROGRAM CODE IS DISPLAYED, PRESS AND HOLD THE FREZZER TEMP DOWN KEYPAD - UNTIL UNIT PROGRAM CODE BEGINS FLASHING INDICATING IT HAS BEEN SAVED. *note* IF YOU ATTEMPT TO ENTER AN INVALID PROGRAM CODE, THE CONTROL WILL NOT SAVE THE NEW CODE, BUT WILL BEEP! (THE UNIT WILL NOT RUN RUN WITH A UNIT PROGRAM CODE OF 0000). ONCE THE PROGRAM CODE HAS BEEN SAVED THE PROGRAMMING MODE IS EXITED BY CLOSING THE FRIG DOORS.  

Posted on Oct 26, 2008

peyton32034

peyton thompson

  • 410 Answers

SOURCE: Maytag MFI2568AES Stainless Steel Bottom

sounds as if the icemaker is getting too much water and causing the unit to flood out. aside from replacing the icemaker you may be able to adj the amount of water going into the icemaker. there is a screw that holds the front cover of the icemaker inplace. remove the cover and you should see a screw  with a + and - sign on it. try turning the screw 1/4 turn then wait for the icemaker to cycle and see if it improves. keep making theses adjustments until your problem is solved thx peyton 

Posted on Jan 28, 2009

Anonymous

  • 126 Answers

SOURCE: maytag refrigerator

IF BOTH WATER AND ICE MAKER ARE NOT WORKING YOU MAIN NEED THE MAIN BOARD. THERE IS NO FUSE.

Posted on Apr 24, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Maytag MFI2568AES- ice maker making ice but cannot harvest


Sounds like the thermostat inside the ice maker that allows the heater to come on during harvest cycle is bad. You will need to replace the ice maker.
Ice Maker Kit For Maytag Refrigerator Model Number MFI2568AES

Sep 24, 2015 | Maytag MFI2568AES Stainless Steel Bottom...

1 Answer

How do I reset or reboot my maytag fridge. I already replaced the control panel. MFI2568AES


SOME FRIDGES HAVE A RESET BUTTON IN THE CONTROL BOARD OR ON THE CONTROL BOARD

Apr 01, 2015 | Maytag Refrigerators

1 Answer

Refrigerator temperature control board


This is the part: http://www.appliancepartspros.com/whirlpool-cntrl-elec-w10890094-ap6027422.html

Its not cheap there is nothing about changing the board for that model.

Apr 18, 2017 | Maytag Refrigerators

1 Answer

Maytag Refrigerator Model Model #MFI2568AES


This a common problem with these units the high voltage in the main control board is the problem, the main control board in the back will need to be replaced. This runs about 250 dollars for the part. You can order it from this link.
http://www.repairclinic.com/Maytag-Refrigerator-Model-MFI2568AES-ID-657261-Parts?n=2

Nov 09, 2013 | Refrigerators

1 Answer

Maytag MFI2568aes:none of the keypad controls work. Is it the control board that is no good?


Check the harness up at the top of the door. Remove the cover and be sure everything is plugged in correctly. Sometimes the harness will work loose do to door movement.

Aug 18, 2012 | Maytag MFI2568AES Stainless Steel Bottom...

1 Answer

Maytag refrigerator


IF BOTH WATER AND ICE MAKER ARE NOT WORKING YOU MAIN NEED THE MAIN BOARD. THERE IS NO FUSE.

Apr 24, 2010 | Maytag MFI2568AES Stainless Steel Bottom...

1 Answer

Maytag Bottom Freezer Fridge 25 cubic ft. Model-MF 12568AES Code- 0302 Serial #- 10040844JN Problem- Control panel not responding and no water and ice through dispenser.


the control panel is a p c board . maytag call's it a jazz board . and will need to be replaced . not a uncommon problem. also the water will work after tempts a stablized . with the new board . one board fits all but has to be programed for your model . this is a job for your appliance tec . the board comes with very good instructions . . if handy with electronics its not hard .. **** hope this helped ..

Apr 04, 2010 | Maytag MFI2568AES Stainless Steel Bottom...

1 Answer

The ice trap door won't stop cycling open and closed and the control panel on the door is blinking all of the lights


Called maytag with model and serial number. This is a very common problem. They sent a new mother board free of charge within a couple of days. You will have to go to the back of the fridge to swap mother boards. It was pretty simple if you have a little patience. Maytag wanted to charge $200 for the service call but it took my husband about twenty minutes. Then you will need to reprogram with the code inside of the door. I was told that this happens alot if there is a power surge, so I now have the fridge on a surge protector. Haven't had a problem since. Hope this helps.

Nov 10, 2009 | Maytag MFI2568AES Stainless Steel Bottom...

2 Answers

Programming code not working


Go to this web page to find the text answer below: http://www.fixya.com/support/t233614-reprogram_hv_board

HERE TIS RIGHT OFF THE INSTRUCTION SHEET.  THE TECH JUST LEFT. POWER UP REF. PROGRAM CODE IS LOCATED ON SERIAL PLATE ON THIS UNIT AFTER THE WORD CODE.-1. PRESS & HOLD THE DOOR ALARM KEYPAD.-2. PRESS & HOLD FREEZER TEMP DOWN KEYPAD.-3. RELEASE DOOR ALARM KEYPAD AND WAIT 3 :WILL DISPLAY PE TO INDICATE PROGRAMMING MODE-5. ENTRY IS CONFIRMED BY PRESSING TEMP DOWN - KEYPAD ONCE MORE.-CONTROL WILL DISPLAY CURRENT PROGRAM CODE. THIS VALUE SHOULD BE VALIDATED THE THE PROGRAM CODE PRINTED ON UNIT SERIAL PLATE.-NOTE: IF PROGRAM CODE IS CORRECT, THE PROGRAMMING MODE IS EXITED BY CLOSING THE FRIG DOOR.-7.PRESS REFRIG TEMP UP KEYPAD + OR REFRIG DOWN KEYPAD -TO CHANGE THE DIGIT VALUE WITH EACH KEY PRESS.-8.THE DECIMAL POINT INDICATES THE SELECTED DIGIT. PRESS THE FREEZER TEMP UP KEYPAD + TO SELECT NEXT DIGIT.-9.ONCE DEIRED PROGRAM CODE IS DISPLAYED, PRESS AND HOLD THE FREZZER TEMP DOWN KEYPAD - UNTIL UNIT PROGRAM CODE BEGINS FLASHING INDICATING IT HAS BEEN SAVED. *note* IF YOU ATTEMPT TO ENTER AN INVALID PROGRAM CODE, THE CONTROL WILL NOT SAVE THE NEW CODE, BUT WILL BEEP! (THE UNIT WILL NOT RUN RUN WITH A UNIT PROGRAM CODE OF 0000). ONCE THE PROGRAM CODE HAS BEEN SAVED THE PROGRAMMING MODE IS EXITED BY CLOSING THE FRIG DOORS.  

Aug 03, 2008 | Maytag MFI2568AES Stainless Steel Bottom...

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

301 people viewed this question

Ask a Question

Usually answered in minutes!

Top Maytag Refrigerators Experts

Marvin
Marvin

Level 3 Expert

85222 Answers

Carlos Alvarez

Level 1 Expert

16 Answers

John Tripp
John Tripp

Level 3 Expert

4656 Answers

Are you a Maytag Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...