What to do when developer spills out on sharp 5520S Machine?

I have filled new developer in my Sharp 5520S copier, but developer spills out, every time I start the machine.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Sharp Master
  • 6,862 Answers

Did you clear the require counter and run the required test before (counters) and test after ward????

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

Posted on Jan 31, 2016

Ad

6 Suggested Answers

6ya6ya

6ya staff

  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Anonymous

  • 146 Answers

SOURCE: Ar-5132 sharp copier

H3-XX codes involve the fusing unit temperature being too low or too high.

Try resetting the error.

[C] – [INTERRUPT] – [0] – [INTERRUPT]
Type in 1 4
Hit [PRINT]
Turn power off then on if it doesn't do it automatically.
If error doesn't reset then you have other trouble
I hope you ran the developer setup and reset all of the parts counters for the items you replaced. Not setting the developer reference can cause a host of problems.
Sim 25-02 adjusts developer.
Sim 42 clears DV counter

Posted on Jun 06, 2008

Bubbabear64

Tim Babcock

  • 2794 Answers

SOURCE: sharp ar5320 developer reset code

The developer doesn't have a reset code.  It uses a calibration program instead with the reset integrated into it.
Even though the copy quality is fine for now, it can change in the next few days.  You should order some developer.

Posted on Sep 18, 2008

rezazadeh

abbas rezazadeh

  • 328 Answers

SOURCE: developer in my sharp ar-5520s mfp

if you want change developer,pullout toner cartridge open blue screw,remove developer unit ,open 3 screws,remove black cover remove old developer and add new

Posted on Jun 01, 2010

Rick Kasper

  • 2072 Answers

SOURCE: toner explosion

You need to either replace the toner cartridge or empty the sump on the front of the cartridge. The waste sump is in the front of the toner cartridge, It has filled up and has nowhere else to go but out of the sump and where ever it lands. Sometimes they fill up before the toner cartridge is empty. It happens

Posted on Jul 30, 2010

Stu Morris K

  • 178 Answers

SOURCE: new machine sharp ar 5320 developer installtion first time

Whats your question here, are you needing help with installation or connecting or is it not functioning after installation

Posted on Dec 03, 2014

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

How to fix the sharp MX-3100N printer? the message on the screen is install the developer.


Developer unit is not detected , or developer is depleted ( which is very bad , because it could mean that it spilled inside your copier , it is very abrasive)

try removing and re-installing the developer unit , and maybe try using another unit for control,
could also be your harness, see if plug of developer unit is plugged into mainbord

Feb 23, 2015 | SHARP MX-3100N

1 Answer

Ar5516 developer spilling out


hi 1 might be developer is very poor quality (generic) 2 check biasing in sharp normally it,s developer issuer and also in this model if u turn mag roller while replacing or just turn and re install in your machine will spill developer

Feb 24, 2014 | Sharp AR-M205 Copier

1 Answer

How to remove waste toner from Sharp AR 5316 is my question - The Procedure, since our office has misplaced the user manual and CDs that which came with the Copier. Now the machine is 15 months old. Now...


The waste toner for this is a cartridge and can be access through the front cover but this cart. is sealed and should not over flow. It sounds like this machine may be dropping developer you can check this with a magnet if the powder you think is toner sticks to it it is DV. If this is the case you need a maintenance and also tell the tech to check the developer toner seal. If they get foled under they will pull dv out of the box.

Aug 27, 2011 | Sharp AR-5316 Advanced Digital Imager...

1 Answer

Need help in replacing my developer.


open front cover.open blue screw. pullout unit ,open 3 screws ,seperate black cover,over it by developer all.fasten 3 screws .fix it then open sticks of toner cartridge.insert it and turn on .add paper(open cassete`s lock.turn on and wait until it goes to ready.give me a top vote.

May 04, 2010 | Sharp AL 800 Copier

1 Answer

Developer in my sharp ar-5520s mfp


if you want change developer,pullout toner cartridge open blue screw,remove developer unit ,open 3 screws,remove black cover remove old developer and add new

Apr 30, 2010 | Sharp SF 2020 Copier

1 Answer

ESTUDIO 45 SPILLING DEVELOPER. BAD COPY QUALITY


Since developer material is spilling, so the developer material is less, thus blur print will occur. The fastest way to solve this issue is to replace a whole new developer unit with new developer material, but this might be quite costly. Otherwise, u need to ask technician to check your machine. Then only can confirm the defects.

Jul 29, 2009 | Toshiba e-Studio 232 Black and White...

1 Answer

Toner spills everywhere


what brand do you use?because No-OEM toner cartridge may be not suit for the Drum Unit? change a OEm toner cartridge to test again.maybe solve this problem.

May 06, 2009 | Sharp AL2040CS Digital Laser Copier,...

1 Answer

Sharp 7900 black copies and low developer


The problem is the drum blade is going bad.This machine is about 15 years old not worth the time or money plus alot of parts are no more.

Jan 24, 2009 | Office Equipment & Supplies

1 Answer

Sharp SF-2014 developer


Hello Gus,
IF the Toner/developer is spilling out towards the rear of the machine then the developer unit is going bad. A common problem with this model was the rear bushings in the developer unit would wear out and start to leak. If you take the developer unit out of the machine, put down some newspaper, and tip the developer unit (OVER THE PAPER) about 15-20 degrees towards the back and see if the Developer/toner leaks out any. If it does then you found the problem.
If it doesn't then you might just have an over toning problem. To check to see if you have an over toning problem, please the developer unit ON THE PAPER, get a philips screw driver, and put it in the rear White gear. You will see a series of gears but there is only 1 that is the located on the END of the Roller with the toner/developer on it. TURN IT CLOCKWISE about 1 turn and see if you see toner spilling out.
If you do, then your machine needs a Developer change.

Hope this helps.
Let me know if you have more questions.
If you need parts for this machine, I have a couple contacts that I can give you and you can see if they have the parts in stock.
Good Luck.
Mac

Jun 26, 2008 | Office Equipment & Supplies

1 Answer

Printing line on the right side of paper


I am unsure of one thing in this post, Is the new toner cartridge still spilling out ink and developer?
Now, from there, you need to get a vacuum with a crevice tool and vacuum the inside of the machine very well. There are ridges and stablizer brackets formed into the frame that the toner and developer fall into and sift out onto the paper.
If your cartridge is still dumping the developer and ink from the same end, I highly suspect the machine is not level from front to back and as the machine runs the toner and developer are moving to that end of the cartridge. Once that happens that cartridge will spill the contents out into the machine.
A thorough cleaning is needed, and even at that, it may take some time for all of the contamination to run itself out. It is difficult to remove all of it.

Mar 25, 2008 | Sharp AL-1655CS Copier

Not finding what you are looking for?
Office Equipment & Supplies Logo

Related Topics:

151 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sharp Office Equipment & Supplies Experts

Anthony Karuku

Level 2 Expert

268 Answers

amir hamza
amir hamza

Level 2 Expert

318 Answers

k24674

Level 3 Expert

8081 Answers

Are you a Sharp Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...