I have a Ademco 6150 keypad and Ademco Vista 20 SE. I do not have the access code, installer code or master codes. When I power up the system I get a d1 and it says "armed". How do I set new codes?

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    New Friend:

    An expert that has 1 follower.

  • Contributor
  • 2 Answers

Within 30 seconds of power up press *and # simultaneously. Display should say 20, if you press *20 1234 then *99 to exit programming. Your system should be disarmed and your install code should now be 1234. You can then use this code to change the master code.

Posted on Dec 08, 2017

Ad

2 Suggested Answers

Anonymous

  • 12 Answers

SOURCE: Ademco Vista 20 programming

You need installer programming manuel.Yes to stay instant.

Posted on Jun 20, 2009

Ad
prakas_3p

Prakash Timilsina

  • 107 Answers

SOURCE: master code setting couldn't do it (alarm system ADEMCO VISTA-10)

hi
menu > settings > security > change lock code > apply master code in place of lock code and press ok > enter new code what you want

Posted on May 08, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

If keypad displays the FC code Can you still program a new master code?


I have never tried that because it has never been requested. "FC" is a higher priority. It means failure to communicate. So I would always correct that problem first and then change the master code. But I don't see why you would not be able to change the master code due to FC code. Gl.

Jan 31, 2015 | Honeywell Ademco Vista 20p And 6150 Keypad...

1 Answer

Trying to change master code on 6150 vista 20


Either you are locked out of installer programming or you do not have a Vista 20...this sounds more like a larger panel such as a Vista 40, 50, or some other 4140 based system...verify the model number by opening the main cabinet. The inside cover should have a diagram of the system and the model number. However, since the boards are easily replaced, the cover label is not always accurate. Look at any labels on the printed circuit board to help you properly id the model. By the way, FC indicates Failure to Communicate, meaning the unit tried to call the monitoring center but could not get through (usually 10 attempts) and is unrelated to the "master code". Hope this helps.

Jan 31, 2015 | Honeywell Ademco Alarm Vista 20p 6150...

1 Answer

Remove FC code Ademco Vista 15P alarm sysem


FC means failure to communicate, call your monitoring company to test your systems communication. If your system uses or used your phone line call on a cell phone so you don't get cut off when you system tries to call to monitoring company. gl

Jun 05, 2014 | Honeywell Ademco Vista 20p And 6150 Keypad...

1 Answer

How do i change my code on an ademco m6673 without knowing the master code?


How to find the master or installer codes for an Ademco ...

security.livewatch.com/.../how-to-find-the-master-or-installer-codes-for-...
Aug 7, 2009 - ... Ademco ?€?Vista series?€ alarm system and you don?€™t knowwhat the codes are. ... The master code is the main user?€™s regular code, but different than the ... Be advised that an installing alarm company will not and should not... The master code can change or add the other SU?€™s as needed ...

Need to reprogram an ADT/ADEMCO system - DoItYourself.com ...

www.doityourself.com/.../295048-need-reprogram-adt-ademco-system.h...
Feb 17, 2007 - Purhased a condominium 2 years ago with an ADT/ADEMCO system. ... Received no manuals of any kind but MAY have gotten a "Security Code" from seller. ... To change the master code the system needs to be in regular run mode, .... myalarm system was working but i went and acted like Reset Master Code for Ademco 4111XM, Via30+ or VISTA 10 ...
Jul 8, 2007
Ademco vista 20P with FC and Comm. Failure
Nov 8, 2005
More results from www.doityourself.com

[PDF]VISTA-20SE, VISTA-20HWSE User Guide - Honeywell ...



Oct 11, 2013 | Vacuums

1 Answer

Trying to get installer code on Honeywell Vista 15-P


hit *20 then put in whatever 4 digits you want as installer code. write this down on your program sheet for future reference. yes, you should have a program record sheet to follow and know how to navigate in programming or else you could make things worse.

Jun 29, 2012 | Honeywell Ademco 6160 Alpha Keypad Vista...

1 Answer

Security code program for ademco alarm 6150


6150 is the type of keypad you have the alarm system itself. The 6150 works on a number of different Honeywell panels. You need to locate the main metal box and open it. There should be a white sticker on the board with the panel type. (Ex. v10,v20, Vista...)

Oct 21, 2011 | Honeywell 5804 Ademco Wireless Security...

1 Answer

How do I program zonig for my Ademco 6148 pad


The 6148 keypad is a fixed english keypad. It is possible to program your system from a fixed english keypad, but it is very difficult. an alpha keypad shows text descriptions of the programming fields. The model number is 6160. If you are doing your own programming, I would suggest replacing the 6148.

When programming, you're programming your alarm panel, not the keypad. The keypad is just an interface to the panel. If you have a tan box in your basement or a closet, that is your panel. There will be a sticker on the inside of the door of the panel that will tell you the model of the panel at the bottom. It will say Ademco Vista 10, 15, 15P, 20, or 20P.

From there you can go to the link below and find the installation and programming manual for your panel.

http://panelguides.com/panel-guides?task=viewcategory&catid=521

Hope this helps.

Mar 18, 2011 | Ademco 10) Ademco 6148 Keypad Fixed...

1 Answer

How to reset ademco after chanhing battery


You have to run a system test. enter your code then press 5. If that does not work try entering your code then press 5 then 0. it all depends on system type. let system test run for about 2-5 minutes it sould reset. Ademco 6150 6150pl3 6150pl2 these identify your keypad model not system type.check your control box to identify your panel. Sould be like Ademco vista 10, 20, 20p

Feb 18, 2011 | Ademco 1 Ademco 6150 6150pl3 6150pl2...

1 Answer

MY ALARM SYSTEM KEEP BEEPING UNCONTROLABLY..ADEMCO ALARM


Resetting Your Installer Code
1. The installer code (IC) is the code that allows you to access the system programming. If you forget your IC, your alarm company probably won't give it to you. This is because they use the same IC for many installed units and keep it a heavy guarded secret. If your forget your IC code, you're going to have to reset it.

First locate and disconnect the transformer. This is a cube-shaped wall outlet, usually placed around the alarm control panel. Next, shut down the alarm system's power supply. You may have to unplug a battery if you have a secondary power source connected to the alarm system. Once the alarm is powered down, you will reconnect the transformer and the battery in that order.

The rest of resetting comes on the keypad. Within 30 seconds of powering up the alarm, go to your alarm key pad press down the * and # keys simultaneously until you see "20" displayed. At the same time, you should see "Installer Code." Enter your new installer code while the "20" is still on the screen. Your installer code will be four digits. The keypad will beep to acknowledge the new installer code. After the keypad beeps, press *99 to exit the program. To check if you have reset the code successfully, enter your new installer code and press 1 (off). The keypad will beep once if you have successfully changed your installer code. If it doesn't beep, repeat the process.
Resetting Your Master Code
2. The master code is usually only used by the home owner. Other users codes can also be set up, including manager, babysitter, gardener and housekeeper codes. The home owner will use the master code to set up these other codes. The master code is also the code you will use when you come home and need to deactivate the alarm before it goes off.

To reset your master code, type in your installer code, press 8, press 02 and then punch in your new master code. Press 1 to turn off the programming. Your keypad will beep when you successfully reset your master code. You can now activate and deactivate your alarm system as you please.


Read more: Ademco Alarm Resetting Instructions ' eHow.com http://www.ehow.com/way_5752912_ademco-alarm-resetting-instructions.html#ixzz3pC2j96jl

Feb 04, 2011 | Audio Players & Recorders

2 Answers

Master code setting couldn't do it (alarm system ADEMCO VISTA-10)


hi
menu > settings > security > change lock code > apply master code in place of lock code and press ok > enter new code what you want

Jun 14, 2009 | Eagle SeaChamp 1000c Recording Sonar...

Not finding what you are looking for?
Home Security Logo

Related Topics:

277 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ademco Home Security Experts

Sean

Level 2 Expert

80 Answers

oooga boooga
oooga boooga

Level 1 Expert

8 Answers

Vincent Migliore
Vincent Migliore

Level 1 Expert

36 Answers

Are you an Ademco Home Security Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...