Question about Copystar CS-1810 Copier
Broken fixing heater wire ? It takes 15 s or more for the fixing temperature to reach 50°C/122°F after the power is turned on or the safety switch is turned off and on. Fixing unit thermistor installed incorrectly. Check and reinstall if necessary. ? It takes 10 s or more for the fixing temperature to reach 100°C/212°F from 50°C/122°F. ? It takes 24 s or more for the fixing temperature to reach the secondary stabilization fixing temperature from the primary stabilization fixing temperature. Fixing unit thermostat triggered. Check for continuity. If none, replace the fixing unit thermostat.
Posted on May 18, 2011
Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
Here's a link to this great service
Good luck!
Posted on Jan 02, 2017