switch of the power and isolate the power cord. To uninstall unthread the two inch discharge port union,then the 1.5 intake port union.

Waterway Pool &... | Answered on Jan 14, 2019


bad multi speed relay or pump motor

Waterway Pool &... | Answered on Jul 04, 2018


perhaps you should take it to motor shop ( google motor rewind and repair in your area).. Electrical motors that run in water should be repaired by insured shop.

Waterway Pool &... | Answered on Apr 12, 2018


There is no fuse in the pump itself. Pump fuses are located in the control pak where the pump cord is attached. Turn off the power to the spa and remove the cover of the pak. There is usually a diagram of the board showing where the fuses are. Pump fuses are not clear they are about 1 1/4" long and have a label on them with the rating of the fuse. Usually 20 or 25 amps and either SC or AG rating

Waterway 5HP... | Answered on Mar 29, 2018


drive out pin and put new handle on then put pin back in

Waterway 1.5hp... | Answered on Feb 03, 2018


The pump motor should have a label on the side of the motor showing a diagram for Common, High speed, Low speed and the right positions for the connections.
Common is always the white wire
High speed is normally red
Low speed is Black
Green wire is always green

Waterway Pool &... | Answered on Feb 01, 2018


To remove the impeller you first take the front face plate off to expose the impeller. Then isolate the shaft from the motor with a pair of needle nose vise grips and using a pair of channel lock pliers grip the end of the impeller and rotate counter clockwise to un thread it from the shaft. If the shaft seal has been leaking there may be to much corrosion to turn the impeller in which case it needs to be broken off.

Waterway 5HP... | Answered on Feb 01, 2018


check recirculation pump and heater element

Waterway 5HP... | Answered on Dec 31, 2017


check side of motor for low vs high voltage

Waterway... | Answered on Dec 05, 2017


less hassle replace whole pump

Waterway... | Answered on Dec 05, 2017


dry out inside you have a short

Waterway Pool &... | Answered on Dec 05, 2017


neutral is the white wires on each power phase phase is the number of hot lines to run pump 120 volt 1 phase 220 volt 2 phase 3 phase has 3 lines to it let electrician handle this

Waterway 5 Hp... | Answered on Dec 05, 2017


impeller screw backwards thread then impeller screws off regular just replace whole pump

Waterway... | Answered on Dec 05, 2017


when cleaning filter grids need to degrease

Waterway 1.5hp... | Answered on Nov 28, 2017


take off basket then unscrew then turn to position

Waterway 1.5hp... | Answered on Sep 15, 2017


if was leaking it ruined bearings in motor replace whole unit

Waterway... | Answered on Sep 15, 2017

Not finding what you are looking for?
Waterway Logo

274 questions posted

Ask a Question

Usually answered in minutes!

Top Waterway Pool & Spa Experts

US Parts Center
US Parts Center

Level 3 Expert

719 Answers

Mike

Level 3 Expert

4367 Answers

Andrew Taylor
Andrew Taylor

Level 3 Expert

30365 Answers

Are you a Waterway Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...